Download
s10103-021-03280-7.pdf 2,06MB
WeightNameValue
1000 Titel
  • Local lung coagulation post resection: an ex-vivo porcine model
1000 Autor/in
  1. Kirschbaum, A. |
  2. Surowiec, Th. M. |
  3. Pehl, A. |
  4. Wiesmann, Th. |
  5. Bartsch, D. K. |
  6. Mirow, N. |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-03-23
1000 Erschienen in
1000 Quellenangabe
  • 37(1):443-447
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s10103-021-03280-7 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7986647/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Following non-anatomical resection of lung parenchyma with a Nd:YAG laser, a coagulated surface remains. As ventilation starts, air leakage may occur in this area. The aim of the present study was to investigate, whether additional coagulation either before or after ventilation has an additional sealing effect. Freshly slaughtered porcine heart-lung blocks were prepared. The trachea was connected to a ventilator. Using a Nd:YAG laser (wavelength: 1320 nm, power: 60 W), round lesions (1.5 cm in diameter) with a depth of 1.5 cm were applied to the lung using an 800-μm laser fiber (5 s per lesion). Group 1 (n = 12) was control. Additional coagulation was performed in group 2 (n = 12) without and in group 3 (n = 12) with ventilation restarted. Air leakage (ml) from the lesions was measured. The thickness of each coagulation layer was determined on histological slices. Differences between individual groups were analyzed by one-way ANOVA (significance p < 0.05). After resection, 26.2 ± 2.7 ml of air emerged from the lesions per single respiration in group 1. Air loss in group 2 was 24.6 ± 2.5 ml (p = 0.07) and in group 3 23.7 ± 1.8 ml (p = 0.0098). In comparison to groups 1 and 2 thickness of the coagulation layers in group 3 was significantly increased. After non-anatomical porcine lung resection with a Nd:YAG laser, additional coagulation of the ventilated resection area can reduce air leakage.
1000 Sacherschließung
lokal Swine [MeSH]
lokal Non-anatomical resection
lokal Pulmonary air leakage
lokal Laser Coagulation [MeSH]
lokal Lung Neoplasms/surgery [MeSH]
lokal Animals [MeSH]
lokal Thorax [MeSH]
lokal Laser bare fiber
lokal Lung/surgery [MeSH]
lokal Original Article
lokal Lasers, Solid-State/therapeutic use [MeSH]
lokal Coagulation
lokal Nd:YAG laser
lokal Laser Therapy [MeSH]
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/S2lyc2NoYmF1bSwgQS4=|https://frl.publisso.de/adhoc/uri/U3Vyb3dpZWMsIFRoLiBNLg==|https://frl.publisso.de/adhoc/uri/UGVobCwgQS4=|https://frl.publisso.de/adhoc/uri/V2llc21hbm4sIFRoLg==|https://frl.publisso.de/adhoc/uri/QmFydHNjaCwgRC4gSy4=|https://frl.publisso.de/adhoc/uri/TWlyb3csIE4u
1000 Hinweis
  • DeepGreen-ID: 434ba09f6df5491c95737dcb2e5f610f ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
  1. Local lung coagulation post resection: an ex-vivo porcine model
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6448963.rdf
1000 Erstellt am 2023-05-04T10:52:36.844+0200
1000 Erstellt von 322
1000 beschreibt frl:6448963
1000 Zuletzt bearbeitet 2023-10-24T07:47:57.239+0200
1000 Objekt bearb. Tue Oct 24 07:47:57 CEST 2023
1000 Vgl. frl:6448963
1000 Oai Id
  1. oai:frl.publisso.de:frl:6448963 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source