Download
s12886-021-02003-4.pdf 974,35KB
WeightNameValue
1000 Titel
  • Short- and long-term agreement and reproducibility of 48-hours intraocular pressure measurements in glaucoma patients
1000 Autor/in
  1. Zimmermann, Marion |
  2. Giers, Bert C. |
  3. Beck, Anna |
  4. Bell, Katharina |
  5. Zimmermann, Herwig |
  6. Hechtner, Marlene |
  7. Hoffmann, Esther M. |
  8. Pfeiffer, Norbert |
  9. Lorenz, Katrin |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-06-21
1000 Erschienen in
1000 Quellenangabe
  • 21(1):262
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s12886-021-02003-4 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218517/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!Glaucomatous eyes often show strong intraocular pressure (IOP) fluctuations and individual measurements at different time points are necessary for personalized therapy. To survey IOP variations 48-hours diurnal and nocturnal IOP measurements were performed on two consecutive days. Aims of this study were to investigate the short-term repeatability of 48-hours measurements within one patient's IOP profile and long-term repeatability between two separate IOP profiles of the same patient.!##!Methods!#!A retrospective cohort study was performed evaluating data of 90 glaucoma patients in a German university medical center between 2006 and 2013. All patients underwent two separate diurnal IOP profiles of 48 h. IOP was measured at 8 am, 2 pm, 6 pm, 9 pm using Goldmann applanation tonometry and at 12 midnight using Perkins tonometry in supine position on two consecutive days. Intraclass correlation coefficients (ICC) were calculated to evaluate agreement for the same time points (each time point agreement) and for consecutive measurements within the IOP profiles (between time point agreement). ICC ≤ 0.4 was defined as poor agreement, 0.4-0.75 as moderate and ≥ 0.75 as excellent. Differences between time points were investigated by Bland Altman plots.!##!Results!#!Each time point measurements of profile 1 showed moderate to excellent agreement (ICCs 0.62-0.93). There was a moderate to excellent agreement for measurements between time points of profile 1 (ICCs day one 0.57-0.86, day two 0.71-0.90). Profile 2 was performed at a median interval of 12.0 months (quartiles 11.0 to 21.0). Each time point agreements within profile 2 showed ICCs from 0.23 to 0.81. It showed moderate to excellent agreement for changes between time points (ICCs 0.53-0.94). Day two demonstrated ICCs from 0.74 to 0.88. Long term IOP repeatability (over both pressure profiles) showed moderate to good agreement (ICCs 0.39-0.67).!##!Conclusions!#!Short and long-term agreement of IOP measurements evaluated by diurnal IOP profiles is moderate to good. Due to mostly moderate agreements, which we believe represent IOP fluctuations, we conclude that it is necessary to perform 48-hours IOP profiles to gain a better overview of the individual IOP fluctuations.
1000 Sacherschließung
lokal 48-hours intraocular pressure profile
lokal Diurnal and nocturnal intraocular pressure measurements
lokal Manometry [MeSH]
lokal Humans [MeSH]
lokal Intraocular pressure
lokal Retrospective Studies [MeSH]
lokal Pressure fluctuation
lokal Glaucoma
lokal Glaucoma/diagnosis [MeSH]
lokal Reproducibility of Results [MeSH]
lokal Tonometry, Ocular [MeSH]
lokal Intraocular Pressure [MeSH]
lokal Circadian Rhythm [MeSH]
lokal Research Article
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/WmltbWVybWFubiwgTWFyaW9u|https://frl.publisso.de/adhoc/uri/R2llcnMsIEJlcnQgQy4=|https://frl.publisso.de/adhoc/uri/QmVjaywgQW5uYQ==|https://frl.publisso.de/adhoc/uri/QmVsbCwgS2F0aGFyaW5h|https://frl.publisso.de/adhoc/uri/WmltbWVybWFubiwgSGVyd2ln|https://frl.publisso.de/adhoc/uri/SGVjaHRuZXIsIE1hcmxlbmU=|https://frl.publisso.de/adhoc/uri/SG9mZm1hbm4sIEVzdGhlciBNLg==|https://frl.publisso.de/adhoc/uri/UGZlaWZmZXIsIE5vcmJlcnQ=|https://frl.publisso.de/adhoc/uri/TG9yZW56LCBLYXRyaW4=
1000 Hinweis
  • DeepGreen-ID: 3e56936870184c6fb14b2f143640e58a ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6462395.rdf
1000 Erstellt am 2023-11-15T12:10:38.639+0100
1000 Erstellt von 322
1000 beschreibt frl:6462395
1000 Zuletzt bearbeitet 2023-11-30T19:47:52.992+0100
1000 Objekt bearb. Thu Nov 30 19:47:52 CET 2023
1000 Vgl. frl:6462395
1000 Oai Id
  1. oai:frl.publisso.de:frl:6462395 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source