Download
12886_2024_Article_3838.pdf 1,33MB
WeightNameValue
1000 Titel
  • Structural reversal of disc cupping measured in Bruch’s membrane opening-based OCT morphometry after PRESERFLO microshunt implantation for open-angle glaucoma
1000 Autor/in
  1. Lüke, Jan Niklas |
  2. Popp, Constantin |
  3. Gietzelt, Caroline |
  4. Steinberg, Florian |
  5. Lüke, Vincent |
  6. Lappa, Alexandra |
  7. Dietlein, Thomas |
  8. Enders, Philip |
1000 Verlag
  • BioMed Central
1000 Erscheinungsjahr 2025
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2025-01-17
1000 Erschienen in
1000 Quellenangabe
  • 25(1):26
1000 Copyrightjahr
  • 2025
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s12886-024-03838-3 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11742539/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • <jats:title>Abstract</jats:title> <jats:sec> <jats:title>Background/ Aims</jats:title> <jats:p>To analyze the longitudinal change in Bruch’s membrane opening minimal rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (pRNFL) thickness using optical coherence tomography (OCT) after implantation of a PRESERFLO® microshunt for surgical glaucoma management in adult glaucoma patients.</jats:p> </jats:sec> <jats:sec> <jats:title>Methods</jats:title> <jats:p>Retrospective data analysis of 59 eyes of 59 participants undergoing implantation of a PRESERFLO microshunt between 2019 and 2022 at a tertiary center for glaucoma management. Surgical management included primary temporary occlusion of the glaucoma shunt to prevent early hypotony. Pre- and post-operative OCT examinations of the optic nerve head (ONH) and intraocular pressure (IOP) were assessed. Longitudinal change in morphometric spectral domain OCT parameters of the ONH was correlated to change in IOP.</jats:p> </jats:sec> <jats:sec> <jats:title>Results</jats:title> <jats:p>BMO-MRW increased significantly between baseline (BL) and follow-up (FU) within the first three months after surgery (BL = 171.15 ± 66.80 μm; FU = 180.78 ± 70.394 μm; <jats:italic>p</jats:italic> = 0.034). For the same postoperative period, the mean preoperative IOP of 24.97 ± 7.22mmHg was lowered after surgery to 13.70 ± 5.09 mmHg. Eighteen months after surgery, there was no significant change in BMO-MRW compared to baseline (BL = 169.83 ± 52.69 μm; FU = 164.98 ± 55.85 μm; <jats:italic>p</jats:italic> = 0.271), while mean IOP was 13.08 ± 4.48 mmHg. A decrease in IOP correlated significantly with a change in BMO-MRW (<jats:italic>r</jats:italic> = 0.453, <jats:italic>p</jats:italic> &lt; 0.05) three months after surgery. Peripapillary RNFL thickness was unchanged in follow-up after three months (<jats:italic>p</jats:italic> &gt; 0.16) and significantly decreased in later follow-up (<jats:italic>p</jats:italic> = 0.009).</jats:p> </jats:sec> <jats:sec> <jats:title>Conclusion</jats:title> <jats:p>PRESERFLO® microshunt implantation with primary temporary occlusion leads to a significant transient increase in BMO-MRW. This phenomenon is also known as structural reversal of disc cupping (SRDC). The effect seems to be less pronounced and of shorter duration when compared to previous data after trabeculectomy with comparable pre- and postoperative IOP levels.</jats:p> </jats:sec>
1000 Sacherschließung
lokal Aged [MeSH]
lokal Intraocular pressure
lokal Coherence tomography
lokal Intraocular Pressure/physiology [MeSH]
lokal Optic Disk/pathology [MeSH]
lokal Male [MeSH]
lokal Nerve Fibers/pathology [MeSH]
lokal Rebound tonometry
lokal Glaucoma, Open-Angle/surgery [MeSH]
lokal Structural reversal
lokal Retinal Ganglion Cells/pathology [MeSH]
lokal Female [MeSH]
lokal Follow-Up Studies [MeSH]
lokal Visual Fields/physiology [MeSH]
lokal Adult [MeSH]
lokal Humans [MeSH]
lokal Optic Disk/diagnostic imaging [MeSH]
lokal Retrospective Studies [MeSH]
lokal Middle Aged [MeSH]
lokal Glaucoma, Open-Angle/physiopathology [MeSH]
lokal Glaucoma
lokal Glaucoma Drainage Implants [MeSH]
lokal Bruch Membrane/diagnostic imaging [MeSH]
lokal Research
lokal Tomography, Optical Coherence/methods [MeSH]
lokal Bruch Membrane/pathology [MeSH]
1000 Fächerklassifikation (DDC)
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/TMO8a2UsIEphbiBOaWtsYXM=|https://frl.publisso.de/adhoc/uri/UG9wcCwgQ29uc3RhbnRpbg==|https://frl.publisso.de/adhoc/uri/R2lldHplbHQsIENhcm9saW5l|https://frl.publisso.de/adhoc/uri/U3RlaW5iZXJnLCBGbG9yaWFu|https://frl.publisso.de/adhoc/uri/TMO8a2UsIFZpbmNlbnQ=|https://frl.publisso.de/adhoc/uri/TGFwcGEsIEFsZXhhbmRyYQ==|https://frl.publisso.de/adhoc/uri/RGlldGxlaW4sIFRob21hcw==|https://frl.publisso.de/adhoc/uri/RW5kZXJzLCBQaGlsaXA=
1000 Hinweis
  • DeepGreen-ID: 03de30dc0516497f8710506f3dab2517 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Förderer
  1. Universitätsklinikum Köln |
1000 Fördernummer
  1. -
1000 Förderprogramm
  1. -
1000 Dateien
1000 Förderung
  1. 1000 joinedFunding-child
    1000 Förderer Universitätsklinikum Köln |
    1000 Förderprogramm -
    1000 Fördernummer -
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6523326.rdf
1000 Erstellt am 2025-07-06T20:50:57.805+0200
1000 Erstellt von 322
1000 beschreibt frl:6523326
1000 Zuletzt bearbeitet 2025-07-30T00:03:18.279+0200
1000 Objekt bearb. Wed Jul 30 00:03:18 CEST 2025
1000 Vgl. frl:6523326
1000 Oai Id
  1. oai:frl.publisso.de:frl:6523326 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source