Download
s41598-020-79237-7.pdf 2,15MB
WeightNameValue
1000 Titel
  • The diagnostic accuracy of isothermal nucleic acid point-of-care tests for human coronaviruses: A systematic review and meta-analysis
1000 Autor/in
  1. Subsoontorn, Pakpoom |
  2. Lohitnavy, Manupat |
  3. Kongkaew, Chuenjid |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-12-18
1000 Erschienen in
1000 Quellenangabe
  • 10:22349
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1038/s41598-020-79237-7 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7749114/ |
1000 Ergänzendes Material
  • https://www.nature.com/articles/s41598-020-79237-7#Sec18 |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Many recent studies reported coronavirus point-of-care tests (POCTs) based on isothermal amplification. However, the performances of these tests have not been systematically evaluated. Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy was used as a guideline for conducting this systematic review. We searched peer-reviewed and preprint articles in PubMed, BioRxiv and MedRxiv up to 28 September 2020 to identify studies that provide data to calculate sensitivity, specificity and diagnostic odds ratio (DOR). Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was applied for assessing quality of included studies and Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) was followed for reporting. We included 81 studies from 65 research articles on POCTs of SARS, MERS and COVID-19. Most studies had high risk of patient selection and index test bias but low risk in other domains. Diagnostic specificities were high (> 0.95) for included studies while sensitivities varied depending on type of assays and sample used. Most studies (n = 51) used reverse transcription loop-mediated isothermal amplification (RT-LAMP) to diagnose coronaviruses. RT-LAMP of RNA purified from COVID-19 patient samples had pooled sensitivity at 0.94 (95% CI: 0.90–0.96). RT-LAMP of crude samples had substantially lower sensitivity at 0.78 (95% CI: 0.65–0.87). Abbott ID Now performance was similar to RT-LAMP of crude samples. Diagnostic performances by CRISPR and RT-LAMP on purified RNA were similar. Other diagnostic platforms including RT- recombinase assisted amplification (RT-RAA) and SAMBA-II also offered high sensitivity (> 0.95). Future studies should focus on the use of un-bias patient cohorts, double-blinded index test and detection assays that do not require RNA extraction.
1000 Sacherschließung
gnd 1206347392 COVID-19
lokal Molecular biology
lokal Molecular medicine
lokal Diseases
lokal Microbiology
lokal Biotechnology
lokal Biochemistry
1000 Fächerklassifikation (DDC)
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/U3Vic29vbnRvcm4sIFBha3Bvb20=|https://frl.publisso.de/adhoc/uri/TG9oaXRuYXZ5LCBNYW51cGF0|https://frl.publisso.de/adhoc/uri/S29uZ2thZXcsIENodWVuamlk
1000 Label
1000 Fördernummer
  1. -
1000 Förderprogramm
  1. -
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6426041.rdf
1000 Erstellt am 2021-03-09T11:15:20.458+0100
1000 Erstellt von 5
1000 beschreibt frl:6426041
1000 Bearbeitet von 25
1000 Zuletzt bearbeitet Fri May 07 08:58:29 CEST 2021
1000 Objekt bearb. Fri May 07 08:58:08 CEST 2021
1000 Vgl. frl:6426041
1000 Oai Id
  1. oai:frl.publisso.de:frl:6426041 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source