  • Plaque characterization using shear wave elastography—evaluation of differentiability and accuracy using a combined ex vivo and in vitro setup
1000 Autor/in
  1. Marlevi, David |
  2. Maksuti, Elira |
  3. Urban, Matthew W. |
  4. Winter, Reidar |
  5. Larsson, Matilda |
1000 Erscheinungsjahr 2018
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2018-11-23
1000 Erschienen in
1000 Quellenangabe
  • 63:235008
1000 Copyrightjahr
  • 2018
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1088/1361-6560/aaec2b |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Ultrasound elastography has shown potential for improved plaque risk stratification. However, no clear consensus exists on what output metric to use, or what imaging parameters would render optimal plaque differentiation. For this reason we developed a combined ex vivo and in vitro setup, in which the ability to differentiate phantom plaques of varying stiffness was evaluated as a function of plaque geometry, push location, imaging plane, and analysed wave speed metric. The results indicate that group velocity or phase velocity  ⩾1 kHz showed the highest ability to significantly differentiate plaques of different stiffness, successfully classifying a majority of the 24 analysed plaque geometries, respectively. The ability to differentiate plaques was also better in the longitudinal views than in the transverse view. Group velocity as well as phase velocities  <1 kHz showed a systematic underestimation of plaque stiffness, stemming from the confined plaque geometries, however, despite this group velocity analysis showed lowest deviation in estimated plaque stiffness (0.1 m s−1 compared to 0.2 m s−1 for phase velocity analysis). SWE results were also invariant to SWE push location, albeit apparent differences in signal-to-noise ratio (SNR) and generated plaque particle velocity. With that, the study has reinforced the potential of SWE for successful plaque differentiation; however the results also highlight the importance of choosing optimal imaging settings and using an appropriate wave speed metric when attempting to differentiate different plaque groups.
1000 Sacherschließung
lokal atherosclerosis
lokal elastography
lokal shear wave elastography
lokal plaque characterization
lokal ultrasound
1000 Fächerklassifikation (DDC)
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0003-1002-2070|https://orcid.org/0000-0002-9654-447X|https://frl.publisso.de/adhoc/uri/VXJiYW4sIE1hdHRoZXcgVy4=|https://frl.publisso.de/adhoc/uri/V2ludGVyLCBSZWlkYXI=|https://frl.publisso.de/adhoc/uri/TGFyc3NvbiwgTWF0aWxkYQ==
1000 Label
1000 Förderer
  1. Vetenskapsrådet |
1000 Fördernummer
  1. VR, 2015-04237
1000 Förderprogramm
  1. -
1000 Dateien
1000 Förderung
  1. 1000 joinedFunding-child
    1000 Förderer Vetenskapsrådet |
    1000 Förderprogramm -
    1000 Fördernummer VR, 2015-04237
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6431837.rdf
1000 Erstellt am 2022-03-01T08:58:07.549+0100
1000 Erstellt von 284
1000 beschreibt frl:6431837
1000 Bearbeitet von 317
1000 Zuletzt bearbeitet 2022-03-18T13:36:34.526+0100
1000 Objekt bearb. Fri Mar 18 13:35:39 CET 2022
1000 Vgl. frl:6431837
1000 Oai Id
  1. oai:frl.publisso.de:frl:6431837 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source