Download
document (38).pdf 238,01KB
WeightNameValue
1000 Titel
  • Input device research for digital pathology : an ergonomic outlook
1000 Autor/in
  1. Alcaraz-Mateos, Eduardo |
  2. Caballero-Aleman, F. |
  3. Albarracin, M. |
  4. Carceles, F. |
  5. Hernandez, R. |
  6. Hernandez-Kakauridze, S. |
  7. Hernandez, L. |
  8. Jimenez, I. |
  9. Lopez, A. |
  10. Moreno, C. |
  11. Perez-Ramos, M. |
  12. Nieto-Olivares, A. |
  13. Sanchez-Campoy, N. |
  14. Martinez-Gonzalez-Moro, I. |
  15. Poblet-Martinez, E. |
1000 Erscheinungsjahr 2016
1000 Publikationstyp
  1. Kongressschrift |
  2. Artikel |
1000 Online veröffentlicht
  • 2016-06-08
1000 Erschienen in
1000 Quellenangabe
  • 1(8):149
1000 Übergeordneter Kongress
1000 Copyrightjahr
  • 2016
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.17629/www.diagnosticpathology.eu-2016-8:149 |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • INtRODUCtION / BACKGROUND: Digital Pathology represents a technological innovation that introduces changes in the traditional work of pathologists. In this regard, an important issue that has not been enough emphasized is the image handling from an ergonomic point of view to avoid work-related musculoskeletal disorders (MSD). AIMS: The aim of this study was to investigate a proper input device for digital pathology. METHODS: Research was conducted in two phases: 1. Comparative study to find an optimal external controller. Eight medical students analyzed 11 input devices: keyboard (HP), conventional mouse (HP), vertical mouse (CLS), touchpad (Logitech), 3 trackballs (Logitech, Kensington Expert and Ulove), Rollermouse (Contour), Ergopointer (Märzhäuser Sensotech), gamepad (Logitech) and a touchless device (Leap-Motion), using them with the Image Viewer software (Ventana). The web-based Fitts´ law test (UC Berkeley) was used to objectify the accuracy of each device, randomly. 12 items were included in the questionnaire: comfort, technical aspects (cursor movement and objective achievement), prospects, overall satisfaction, prior experience, and others. 2. Evaluation by two experienced pathologists (MPR and ANO, 55 and 50 year-old, respectively) the best rated input device and comparison with a voice recognition system (Invox Medical Dictation) using a headset microphone (Plantronics), rating perceived workload using NASA Task Load Index with 28 whole slide images. Digital Image Hub (Leica) with a 4 MegaPixel display (Barco) was used. Data were processed with SPSS 21.0. RESULTS: Correlation between technical aspects of the evaluated devices and accuracy (Fitts´ law test), and comfort with overall satisfaction existed (p<0.05). The assessment concluded that vertical mouse was the best rated input device. However, it has a slightly higher perceived workload in comparison with the voice recognition system, which was the proper controller for digital pathology in this study. CONCLUSION: We describe a methodology that can study and compare input devices for future workstations in digital pathology. Pathologists should be involved in this process trying to find ergonomic devices that prevent MSD. Voice recognition can function as a good handsfree device for digital pathology and could be considered in physical disability situations. Further studies using electromyography, accelerometry and 3D reconstruction analysis could provide additional ergonomic information.
1000 Fächerklassifikation (DDC)
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/QWxjYXJhei1NYXRlb3MsIEVkdWFyZG8=|https://frl.publisso.de/adhoc/uri/Q2FiYWxsZXJvLUFsZW1hbiwgRi4=|https://frl.publisso.de/adhoc/uri/QWxiYXJyYWNpbiwgTS4=|https://frl.publisso.de/adhoc/uri/Q2FyY2VsZXMsIEYu|https://frl.publisso.de/adhoc/uri/SGVybmFuZGV6LCBSLg==|https://frl.publisso.de/adhoc/uri/SGVybmFuZGV6LUtha2F1cmlkemUsIFMu|https://frl.publisso.de/adhoc/uri/SGVybmFuZGV6LCBMLiA=|https://frl.publisso.de/adhoc/uri/SmltZW5leiwgSS4=|https://frl.publisso.de/adhoc/uri/TG9wZXosIEEu|https://frl.publisso.de/adhoc/uri/TW9yZW5vLCBDLg==|https://frl.publisso.de/adhoc/uri/UGVyZXotUmFtb3MsIE0u|https://frl.publisso.de/adhoc/uri/TmlldG8tT2xpdmFyZXMsIEEu|https://frl.publisso.de/adhoc/uri/U2FuY2hlei1DYW1wb3ksIE4u|https://frl.publisso.de/adhoc/uri/TWFydGluZXotR29uemFsZXotTW9ybywgSS4=|https://frl.publisso.de/adhoc/uri/UG9ibGV0LU1hcnRpbmV6LCBFLg==
1000 Label
1000 Förderer
  1. Verein für den biol. technol. Fortschritt in der Medizin, Heidelberg |
1000 Fördernummer
  1. -
1000 Förderprogramm
  1. -
1000 Dateien
  1. Input device research for digital pathology : an ergonomic outlook
1000 Förderung
  1. 1000 joinedFunding-child
    1000 Förderer Verein für den biol. technol. Fortschritt in der Medizin, Heidelberg |
    1000 Förderprogramm -
    1000 Fördernummer -
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6432159.rdf
1000 Erstellt am 2022-03-11T19:22:32.580+0100
1000 Erstellt von 218
1000 beschreibt frl:6432159
1000 Bearbeitet von 25
1000 Zuletzt bearbeitet 2022-08-18T13:07:55.093+0200
1000 Objekt bearb. Thu Aug 18 12:49:48 CEST 2022
1000 Vgl. frl:6432159
1000 Oai Id
  1. oai:frl.publisso.de:frl:6432159 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source