Download
Upload.pdf 367,90KB
WeightNameValue
1000 Titel
  • Comparative sensitivity evaluation for 122 CE-marked rapid diagnostic tests for SARS-CoV-2 antigen, Germany, September 2020 to April 2021
1000 Autor/in
  1. Scheiblauer, Heinrich |
  2. Filomena, Angela |
  3. Nitsche, Andreas |
  4. Puyskens, Andreas |
  5. Corman, Victor Max |
  6. Drosten, Christian |
  7. Zwirglmaier, Katrin |
  8. Lange, Constanze |
  9. Emmerich, Petra |
  10. Müller, Michael |
  11. Knauer, Olivia |
  12. Nübling, Claudius Micha |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-11-04
1000 Erschienen in
1000 Quellenangabe
  • 26(44):pii=2100441
1000 FRL-Sammlung
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.2807/1560-7917.ES.2021.26.44.2100441 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8569926/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • INTRODUCTION: Numerous CE-marked SARS-CoV-2 antigen rapid diagnostic tests (Ag RDT) are offered in Europe, several of them with unconfirmed quality claims. AIM: We performed an independent head-to-head evaluation of the sensitivity of SARS-CoV-2 Ag RDT offered in Germany. METHODS: We addressed the sensitivity of 122 Ag RDT in direct comparison using a common evaluation panel comprised of 50 specimens. Minimum sensitivity of 75% for panel specimens with a PCR quantification cycle (Cq) ≤ 25 was used to identify Ag RDT eligible for reimbursement in the German healthcare system. RESULTS: The sensitivity of different SARS-CoV-2 Ag RDT varied over a wide range. The sensitivity limit of 75% for panel members with Cq ≤ 25 was met by 96 of the 122 tests evaluated; 26 tests exhibited lower sensitivity, few of which failed completely. Some RDT exhibited high sensitivity, e.g. 97.5 % for Cq < 30. CONCLUSIONS: This comparative evaluation succeeded in distinguishing less sensitive from better performing Ag RDT. Most of the evaluated Ag RDT appeared to be suitable for fast identification of acute infections associated with high viral loads. Market access of SARS-CoV-2 Ag RDT should be based on minimal requirements for sensitivity and specificity.
1000 Sacherschließung
gnd 1206347392 COVID-19
1000 Fächerklassifikation (DDC)
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0003-1624-8310|https://orcid.org/0000-0002-2301-4021|https://orcid.org/0000-0001-8185-3176|https://orcid.org/0000-0002-6492-9463|https://orcid.org/0000-0002-3605-0136|https://orcid.org/0000-0001-7923-0519|https://orcid.org/0000-0001-8598-9572|https://frl.publisso.de/adhoc/uri/ICBMYW5nZSwgQ29uc3RhbnplICAgIA==|https://orcid.org/0000-0001-5093-4539|https://frl.publisso.de/adhoc/uri/ICAgTcO8bGxlciwgTWljaGFlbCAgICA=|https://d-nb.info/gnd/143310690|https://orcid.org/0000-0002-5892-4105
1000 Label
1000 Fördernummer
  1. -
1000 Förderprogramm
  1. -
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6432191.rdf
1000 Erstellt am 2022-03-14T10:41:58.503+0100
1000 Erstellt von 323
1000 beschreibt frl:6432191
1000 Bearbeitet von 317
1000 Zuletzt bearbeitet Mon Apr 25 09:50:49 CEST 2022
1000 Objekt bearb. Mon Apr 25 09:49:52 CEST 2022
1000 Vgl. frl:6432191
1000 Oai Id
  1. oai:frl.publisso.de:frl:6432191 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source