Download
document (56).pdf 512,53KB
WeightNameValue
1000 Titel
  • Optimizing Optical And Digital Resolution For Brightfield Whole Slide Scanning
1000 Autor/in
  1. Isola, J. |
  2. Ylinen, O. |
  3. Tolonen, T. |
  4. Tolonen, P. |
1000 Erscheinungsjahr 2016
1000 Publikationstyp
  1. Kongressschrift |
  2. Artikel |
1000 Online veröffentlicht
  • 2016-06-08
1000 Erschienen in
1000 Quellenangabe
  • 1(8):165
1000 Übergeordneter Kongress
1000 Copyrightjahr
  • 2016
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.17629/www.diagnosticpathology.eu-2016-8:165 |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • INTRODUCTION / BACKGROUND: Whole slide imaging lacks standards for defining image resolution. Scanner vendors usually describe the image resolution according to the microscope objectives “20X” or “40X”. This has caused confusion, since scanning with a 20X objective lens may mean spatial resolution 0.25 to 0.5 microns per pixel, due to variable pixel size of the camera sensor and/or use of a magnifying relay lens. AIMS: Our aim was to compare image quality obtained by two digital cameras (with pixel sizes 5.5um and 3.1um conbined with 10X, 20X, and 40X Plan Apo objective lenses. METHODS: As for image quality readouts we used standardized resolution charts, Peak-Signal-To-Noise Ratio, and evaluation by three pathologists who ranked the images by their “visually lossless quality”, when displayed with a 4K computer monitor. Lossless JPEG2000 was used as a reference. RESULTS: The differences in scanned image quality were significant. The image quality achieved with a CCD camera with 3.1 um pixels was superior in all tests. It was noteworthy that the camera with 3.1 um pixels (Lumenera 1265R) gave visually as good diagnostic image quality with 10X lens (0.31 um/pixel) as did the 5.5 um pixel camera (Lumenera LT425) with 20X lens (0.28 um/pixel). This gives a significant speed advantage in scanning of standard H&E slides, because the scanner needs to capture only one 10X field instead of four 20X fields. In higher resolution scanning tasks, such as cytology and in situ hybridization, we found 3.1 um pixel Lumenera 1265R camera and Plan-Apo 20X lens to give diagnostically satisfactory scanning results. We anticipate that in the future scanners will be equipped with cameras having small pixel size sensors (typically 2-3microns). This matches with the optical resolution of Plan-Apo objective lenses. Compared to current scanners, significant image quality and/or scanning speed improvement can be gained by upgrading the camera.
1000 Fächerklassifikation (DDC)
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/SXNvbGEsIEou|https://frl.publisso.de/adhoc/uri/WWxpbmVuLCBPLg==|https://frl.publisso.de/adhoc/uri/VG9sb25lbiwgVC4=|https://frl.publisso.de/adhoc/uri/VG9sb25lbiwgUC4=
1000 Label
1000 Förderer
  1. Verein für den biol. technol. Fortschritt in der Medizin, Heidelberg |
1000 Fördernummer
  1. -
1000 Förderprogramm
  1. -
1000 Dateien
1000 Förderung
  1. 1000 joinedFunding-child
    1000 Förderer Verein für den biol. technol. Fortschritt in der Medizin, Heidelberg |
    1000 Förderprogramm -
    1000 Fördernummer -
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6432498.rdf
1000 Erstellt am 2022-03-25T13:46:27.805+0100
1000 Erstellt von 218
1000 beschreibt frl:6432498
1000 Bearbeitet von 218
1000 Zuletzt bearbeitet 2022-08-18T13:09:35.072+0200
1000 Objekt bearb. Thu May 12 19:33:06 CEST 2022
1000 Vgl. frl:6432498
1000 Oai Id
  1. oai:frl.publisso.de:frl:6432498 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source