Download
ORE514916.pdf 678,41KB
WeightNameValue
1000 Titel
  • IOL Formula Constants: Strategies for Optimization and Defining Standards for Presenting Data
1000 Autor/in
  1. Langenbucher, Achim |
  2. Szentmáry, Nóra |
  3. Cayless, Alan |
  4. Müller, Michael |
  5. Eppig, Timo |
  6. Schröder, Simon |
  7. Fabian, Ekkehart |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-02-02
1000 Erschienen in
1000 Quellenangabe
  • 64(6):1055-1067
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1159/000514916 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8743903/ |
1000 Publikationsstatus
1000 Abstract/Summary
  • Purpose!#!The aim of this study is to present strategies for optimization of lens power (IOLP) formula constants and to show options how to present the results adequately.!##!Methods!#!A dataset of N = 1,601 preoperative biometric values, IOLP data and postoperative refraction data was split into a training set and a test set using a random sequence. Based on the training set, we calculated the formula constants for established lens calculation formulae with different methods. Based on the test set, we derived the formula prediction error (PE) as difference of the achieved refraction from the formula predicted refraction.!##!Results!#!For formulae with 1 constant, it is possible to back-calculate the individual constant for each case using formula inversion. However, this is not possible for formulae with >1 constant. In these cases, more advanced concepts such as non-linear optimization strategies are necessary to derive the formula constants. During cross-validation, measures such as the mean absolute or the root mean squared PE or the ratio of cases within mean absolute PE (MAE) limits could be used as quality measures.!##!Conclusions!#!Different constant optimization concepts yield different results. To test the performance of optimized formula constants, a cross-validation strategy is mandatory. We recommend performance curves, where the ratio of cases within absolute PE limits is plotted against the MAE.
1000 Sacherschließung
lokal Refraction, Ocular [MeSH]
lokal Optics and Photonics [MeSH]
lokal Lens power calculation formulae
lokal Humans [MeSH]
lokal Retrospective Studies [MeSH]
lokal Biometry [MeSH]
lokal Customized constants
lokal Formula constant optimization
lokal Non-linear optimization
lokal Phacoemulsification [MeSH]
lokal Visual Acuity [MeSH]
lokal Lenses, Intraocular [MeSH]
lokal Lens Implantation, Intraocular [MeSH]
lokal Research Article
lokal Mean absolute prediction error
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/TGFuZ2VuYnVjaGVyLCBBY2hpbQ==|https://frl.publisso.de/adhoc/uri/U3plbnRtw6FyeSwgTsOzcmE=|https://orcid.org/0000-0003-0779-7449|https://frl.publisso.de/adhoc/uri/TcO8bGxlciwgTWljaGFlbA==|https://frl.publisso.de/adhoc/uri/RXBwaWcsIFRpbW8=|https://frl.publisso.de/adhoc/uri/U2NocsO2ZGVyLCBTaW1vbg==|https://frl.publisso.de/adhoc/uri/RmFiaWFuLCBFa2tlaGFydA==
1000 Hinweis
  • DeepGreen-ID: 21439b1fb27f46b9bb798a2587114015 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6440027.rdf
1000 Erstellt am 2023-01-30T09:17:58.461+0100
1000 Erstellt von 322
1000 beschreibt frl:6440027
1000 Zuletzt bearbeitet Sat Oct 14 16:22:30 CEST 2023
1000 Objekt bearb. Sat Oct 14 16:22:30 CEST 2023
1000 Vgl. frl:6440027
1000 Oai Id
  1. oai:frl.publisso.de:frl:6440027 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source