Download
TMH519700.pdf 432,90KB
WeightNameValue
1000 Titel
  • 10 Years of Experience with the First Thawed Plasma Bank in Germany
1000 Autor/in
  1. Selleng, Kathleen |
  2. Greinacher, Andreas |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-10-08
1000 Erschienen in
1000 Quellenangabe
  • 48(6):350-357
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1159/000519700 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8739389/ |
1000 Publikationsstatus
1000 Abstract/Summary
  • Background!#!Plasma is stored at -30°C, which requires thawing before transfusion, causing a time delay between ordering and issuing of at least 30 min. In case of bleeding emergencies, guidelines strongly recommend a 2:1 transfusion ratio of RBCs and plasma. In addition, each minute delay in issuing of blood products in bleeding emergencies increases the mortality risk. To provide plasma in time in bleeding emergencies, a thawed plasma bank was introduced in 2011.!##!Summary!#!The thawed plasma bank of University Medicine Greifswald has provided 18,924 thawed stored plasma units between 2011 and 2020. The workflow in the laboratory as well as in the emergency room, the operating room, and the intensive care unit have been optimized by thawed stored plasma. In case of emergencies, the stress factor for the transfusion medicine laboratory staff has been reduced substantially. The thawed plasma bank allows to transfuse patients with massive transfusion demand at a 2:1 ratio of RBCs and plasma according to guidelines. To reduce storage time, we issue all plasma requests from the thawed plasma bank except for pediatric patients. This results in a median storage time in the thawed plasma bank of 24 h. The 'just in time' availability of plasma within the entire hospital based on the thawed plasma bank has reduced precautionary ordering of plasma, and hereby the unnecessary use of plasma. After introduction of the thawed plasma bank, plasma usage decreased substantially by 24% within the first year and by 60% compared to 2019/2020. However, as the overall approach to using blood products has changed over the last 10 years due to the patient blood management initiative, quantification of the effects of the thawed plasma bank in reduction of plasma transfusion is difficult.!##!Key messages!#!(1) A thawed plasma bank for the routine supply of blood products in a large hospital is feasible in Germany. (2) The thawed plasma bank allows to supply RBCs and plasma in a 2:1 ratio in bleeding emergencies. (3) The beneficial logistical effects of the thawed plasma bank are optimal if all plasma requests are supplied from the thawed plasma bank. This results in a median storage time of 24 h for thawed plasma.
1000 Sacherschließung
lokal Thawed plasma bank
lokal Review Article
lokal Liquid plasma
lokal Clotting factor stability
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/U2VsbGVuZywgS2F0aGxlZW4=|https://orcid.org/0000-0001-8343-7336
1000 Hinweis
  • DeepGreen-ID: 411b19e074d54641b86f8f415b79f1fb ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6440033.rdf
1000 Erstellt am 2023-01-30T09:18:59.904+0100
1000 Erstellt von 322
1000 beschreibt frl:6440033
1000 Zuletzt bearbeitet Sat Oct 14 09:44:57 CEST 2023
1000 Objekt bearb. Sat Oct 14 09:44:57 CEST 2023
1000 Vgl. frl:6440033
1000 Oai Id
  1. oai:frl.publisso.de:frl:6440033 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source