Download
s00066-020-01596-x.pdf 2,19MB
WeightNameValue
1000 Titel
  • Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients
1000 Autor/in
  1. Böckelmann, Felix |
  2. Putz, Florian |
  3. Kallis, Karoline |
  4. Lettmaier, Sebastian |
  5. Fietkau, Rainer |
  6. Bert, Christoph |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-03-10
1000 Erschienen in
1000 Quellenangabe
  • 196(7):647-656
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00066-020-01596-x |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7305089/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Purpose!#!To investigate the dosimetric influence of daily interfractional (inter) setup errors and intrafractional (intra) target motion on the planning target volume (PTV) and the possibility of an offline adaptive radiotherapy (ART) method to correct larger patient positioning uncertainties in image-guided radiotherapy for prostate cancer (PCa).!##!Materials and methods!#!A CTV (clinical target volume)-to-PTV margin ranging from 15 mm in LR (left-right) and SI (superior-inferior) and 5-10 mm in AP (anterior-posterior) direction was applied to all patients. The dosimetric influence of this margin was retrospectively calculated by analysing systematic and random components of inter and intra errors of 31 consecutive intermediate- and high-risk localized PCa patients using daily cone beam computed tomography and kV/kV (kilo-Voltage) imaging. For each patient inter variation was assessed by observing the first 4 treatment days, which led to an offline ART-based treatment plan in case of larger variations.!##!Results!#!Systematic inter uncertainties were larger (1.12 in LR, 2.28 in SI and 1.48 mm in AP) than intra systematic errors (0.44 in LR, 0.69 in SI and 0.80 mm in AP). Same findings for the random error in SI direction with 3.19 (inter) and 2.30 mm (intra), whereas in LR and AP results were alike with 1.89 (inter) and 1.91 mm (intra) and 2.10 (inter) and 2.27 mm (intra), respectively. The calculated margin revealed dimensions of 4-5 mm in LR, 8-9 mm in SI and 6-7 mm in AP direction. Treatment plans which had to be adapted showed smaller variations with 1.12 (LR) and 1.72 mm (SI) for Σ and 4.17 (LR) and 3.75 mm (SI) for σ compared to initial plans with 1.77 and 2.62 mm for Σ and 4.46 and 5.39 mm for σ in LR and SI, respectively.!##!Conclusion!#!The currently clinically used margin of 15 mm in LR and SI and 5-10 mm in AP direction includes inter and intra uncertainties. The results show that offline ART is feasible which becomes a necessity with further reductions in PTV margins.
1000 Sacherschließung
lokal Aged, 80 and over [MeSH]
lokal Cone-Beam Computed Tomography/methods [MeSH]
lokal Aged [MeSH]
lokal Prostate-Specific Antigen/blood [MeSH]
lokal Drinking protocol
lokal Motion [MeSH]
lokal Prostatic Neoplasms/blood [MeSH]
lokal Prostatic Neoplasms/radiotherapy [MeSH]
lokal Original Article
lokal Rectum/radiation effects [MeSH]
lokal Male [MeSH]
lokal Patient Positioning [MeSH]
lokal Adenocarcinoma/radiotherapy [MeSH]
lokal Dose Fractionation, Radiation [MeSH]
lokal Combined Modality Therapy [MeSH]
lokal Adenocarcinoma/diagnostic imaging [MeSH]
lokal Endorectal balloon
lokal Prostatic Neoplasms/surgery [MeSH]
lokal Adenocarcinoma/blood [MeSH]
lokal Radiotherapy, Intensity-Modulated/methods [MeSH]
lokal Uncertainty [MeSH]
lokal Radiotherapy Planning, Computer-Assisted [MeSH]
lokal Cone beam computed tomography
lokal Humans [MeSH]
lokal Retrospective Studies [MeSH]
lokal Artifacts [MeSH]
lokal Fiducial Markers [MeSH]
lokal Prostatic Neoplasms/diagnostic imaging [MeSH]
lokal Organs at Risk/radiation effects [MeSH]
lokal Margin calculation
lokal Prostatectomy [MeSH]
lokal Radiotherapy Dosage [MeSH]
lokal Adenocarcinoma/surgery [MeSH]
lokal Radiotherapy, Image-Guided/methods [MeSH]
lokal Radiotherapy Setup Errors [MeSH]
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/QsO2Y2tlbG1hbm4sIEZlbGl4|https://frl.publisso.de/adhoc/uri/UHV0eiwgRmxvcmlhbg==|https://frl.publisso.de/adhoc/uri/S2FsbGlzLCBLYXJvbGluZQ==|https://frl.publisso.de/adhoc/uri/TGV0dG1haWVyLCBTZWJhc3RpYW4=|https://frl.publisso.de/adhoc/uri/RmlldGthdSwgUmFpbmVy|https://orcid.org/0000-0002-8539-6600
1000 Hinweis
  • DeepGreen-ID: 22721dbdd19c45bbb0529f388241f0e6 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6441852.rdf
1000 Erstellt am 2023-04-26T09:51:49.557+0200
1000 Erstellt von 322
1000 beschreibt frl:6441852
1000 Zuletzt bearbeitet Thu Oct 19 11:17:14 CEST 2023
1000 Objekt bearb. Thu Oct 19 11:17:14 CEST 2023
1000 Vgl. frl:6441852
1000 Oai Id
  1. oai:frl.publisso.de:frl:6441852 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source