Download
s10195-021-00568-w.pdf 1,51MB
WeightNameValue
1000 Titel
  • Removal of cement-augmented screws in distal femoral fractures and the effect of retained screws and cement on total knee arthroplasty: a biomechanical investigation
1000 Autor/in
  1. Wähnert, Dirk |
  2. Grüneweller, Niklas |
  3. Gueorguiev, Boyko |
  4. Vordemvenne, Thomas |
  5. Gehweiler, Dominic |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-02-27
1000 Erschienen in
1000 Quellenangabe
  • 22(1):5
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s10195-021-00568-w |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7914321/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!Given the increasing number of osteoporotic fractures of the distal femur, screw augmentation with bone cement is an option to enhance implant anchorage. However, in implant removal or revision surgeries, the cement cannot be removed from the distal femur without an extended surgical procedure. Therefore, the aims of this study were to investigate (1) whether cement augmentation has any influence on screw removal and removal torque, and (2) whether the implantation of a femoral component of a knee arthroplasty and its initial interface stability are affected by the remaining screws/cement.!##!Material and methods!#!Eight pairs of fresh-frozen human female cadaveric distal femurs (mean age, 86 years) with a simulated AO/OTA 33 A3 fracture were randomized in paired fashion to two groups and fixed with a distal femoral locking plate using cannulated perforated locking screws. Screw augmentation with bone cement was performed in one of the groups, while the other group received no screw augmentation. Following biomechanical testing until failure (results published separately), the screws were removed and the removal torque was measured. A femoral component of a knee arthroplasty was then implanted, and pull-out tests were performed after cement curing. Interference from broken screws/cement was assessed, and the maximum pull-out force was measured.!##!Results!#!The mean screw removal torque was not significantly different between the augmented (4.9 Nm, SD 0.9) and nonaugmented (4.6 Nm, SD 1.3, p = 0.65) screw groups. However, there were significantly more broken screws in in the augmented screw group (17 versus 9; p < 0.001). There was no significant difference in the pull-out force of the femoral component between the augmented (2625 N, SD 603) and nonaugmented (2653 N, SD 542, p = 0.94) screw groups.!##!Conclusion!#!The screw removal torque during implant removal surgery does not significantly differ between augmented and nonaugmented screws. In the augmented screw group, significantly more screws failed. To overcome this, the use of solid screws in holes B, C, and G can be considered. Additionally, it is possible to implant a femoral component for knee arthroplasty that retains the initial anchorage and does not suffer from interference with broken screws and/or residual cement.!##!Level of evidence!#!5.
1000 Sacherschließung
lokal Female [MeSH]
lokal Aged, 80 and over [MeSH]
lokal Device Removal/methods [MeSH]
lokal Humans [MeSH]
lokal Bone Cements [MeSH]
lokal Biomechanical Phenomena [MeSH]
lokal Biomechanics
lokal Osteoporosis
lokal Reoperation [MeSH]
lokal Bone Screws [MeSH]
lokal Bone Plates [MeSH]
lokal Femoral Fractures/surgery [MeSH]
lokal Original Article
lokal Total knee arthroplasty
lokal Screw augmentation
lokal Femoral Fractures/physiopathology [MeSH]
lokal Cadaver [MeSH]
lokal Fracture Fixation, Internal/methods [MeSH]
lokal Arthroplasty, Replacement, Knee/methods [MeSH]
lokal Distal femoral fracture
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-2352-7951|https://frl.publisso.de/adhoc/uri/R3LDvG5ld2VsbGVyLCBOaWtsYXM=|https://orcid.org/0000-0001-9795-115X|https://frl.publisso.de/adhoc/uri/Vm9yZGVtdmVubmUsIFRob21hcw==|https://orcid.org/0000-0001-7148-9569
1000 Hinweis
  • DeepGreen-ID: 887b1d54123f4c9eac0d41e9988ab1ec ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6442394.rdf
1000 Erstellt am 2023-04-26T14:11:48.575+0200
1000 Erstellt von 322
1000 beschreibt frl:6442394
1000 Zuletzt bearbeitet 2023-10-19T12:32:52.313+0200
1000 Objekt bearb. Thu Oct 19 12:32:52 CEST 2023
1000 Vgl. frl:6442394
1000 Oai Id
  1. oai:frl.publisso.de:frl:6442394 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source