Download
s10194-021-01355-y.pdf 801,31KB
WeightNameValue
1000 Titel
  • Age- and frequency-dependent changes in dynamic contrast perception in visual snow syndrome
1000 Autor/in
  1. Eren, Ozan Emre |
  2. Straube, Andreas |
  3. Schöberl, Florian |
  4. Ruscheweyh, Ruth |
  5. Eggert, Thomas |
  6. Schankin, Christoph J. |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-12-11
1000 Erschienen in
1000 Quellenangabe
  • 22(1):148
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s10194-021-01355-y |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8903496/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Objective!#!Patients with visual snow syndrome (VSS) suffer from a debilitating continuous ('TV noise-like') visual disturbance. They report problems with vision at night and palinopsia despite normal visual acuity. The underlying pathophysiology of VSS is largely unknown. Currently, it is a clinical diagnosis based on the patient's history, an objective test is not available. Here, we tested the hypothesis that patients with VSS have an increased threshold for detecting visual contrasts at particular temporal frequencies by measuring dynamic contrast detection-thresholds.!##!Methods!#!Twenty patients with VSS were compared to age-, gender-, migraine- and aura-matched controls in this case-control study. Subjects were shown bars randomly tilted to the left or right, flickering at six different frequencies (15 Hz, 20 Hz, 25 Hz, 30 Hz, 35 Hz, 40 Hz). The contrast threshold (CT) for detection of left or right tilt was measured in a two-alternative adaptive forced-choice procedure (QUEST). The threshold was defined as the Michelson contrast necessary to achieve the correct response in 75% of the cases.!##!Results!#!The CT increased for higher flicker frequencies (ANOVA: main effect frequency: F (5,180) = 942; p < 0.001), with an additional significant frequency*diagnosis interaction (ANOVA: F (5,180) = 5.00; p < 0.001). This interaction effect was due to an increased CT at a flicker frequency of 15 Hz in the VSS cohort (VSS: MC = 1.17%; controls: MC = 0.77%). At the other frequencies, group comparisons revealed no differences. Furthermore, in the VSS cohort we observed an increase of CT with higher age (r = 0.69; p < 0.001), which was not seen in controls (r = 0.30; p = 0.20).!##!Conclusions!#!This study demonstrates a lower visual contrast sensitivity exclusively at 15 Hz in VSS patients and demonstrates frequency-dependent differences in dynamic contrast vision. The peak sensitivities of both parvo- and magnocellular visual pathways are close to a frequency of about 10 Hz. Therefore, this frequency seems to be of crucial importance in everyday life. Thus, it seems plausible that the impairment of contrast sensitivity at 15 Hz might be an important pathophysiological correlate of VSS. Furthermore, the overall age-related decrease in contrast sensitivity only in VSS patients underscores the vulnerability of dynamic contrast detection in VSS patients. Dynamic CT detection seems to be a promising neurophysiological test that may contribute to the diagnosis of VSS.
1000 Sacherschließung
lokal Visual acuity
lokal Contrast Sensitivity [MeSH]
lokal Humans [MeSH]
lokal Visual snow syndrome
lokal Case-Control Studies [MeSH]
lokal Dynamic contrast perception
lokal Contrast threshold
lokal Research Article
lokal Vision Disorders/diagnosis [MeSH]
lokal Visual Pathways [MeSH]
lokal Migraine Disorders [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-5299-388X|https://frl.publisso.de/adhoc/uri/U3RyYXViZSwgQW5kcmVhcw==|https://frl.publisso.de/adhoc/uri/U2Now7ZiZXJsLCBGbG9yaWFu|https://frl.publisso.de/adhoc/uri/UnVzY2hld2V5aCwgUnV0aA==|https://frl.publisso.de/adhoc/uri/RWdnZXJ0LCBUaG9tYXM=|https://frl.publisso.de/adhoc/uri/U2NoYW5raW4sIENocmlzdG9waCBKLg==
1000 Hinweis
  • DeepGreen-ID: bbc59ef697d342b5a17d331865e514f4 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6442396.rdf
1000 Erstellt am 2023-04-26T14:12:19.796+0200
1000 Erstellt von 322
1000 beschreibt frl:6442396
1000 Zuletzt bearbeitet 2023-10-19T12:33:10.318+0200
1000 Objekt bearb. Thu Oct 19 12:33:10 CEST 2023
1000 Vgl. frl:6442396
1000 Oai Id
  1. oai:frl.publisso.de:frl:6442396 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source