Download
s00066-020-01714-9.pdf 159,03KB
WeightNameValue
1000 Titel
  • Randomisierte Phase-IIB-Studie zur Protonentherapie vs. intensitätsmodulierte Photonentherapie für lokal fortgeschrittene Ösophaguskarzinome
1000 Titelzusatz
  • Proton beam therapy versus intensity-modulated radiation therapy for locally advanced esophageal cancer: a randomized phase IIB trial
1000 Autor/in
  1. Krause, Mechthild |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-11-30
1000 Erschienen in
1000 Quellenangabe
  • 197(1):79-81
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00066-020-01714-9 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7801348/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Purpose!#!This study aims to evaluate the best possible practice using hybrid volumetric modulated arc therapy (H-VMAT) for hypofractionated radiation therapy of breast cancer. Different combinations of H‑VMAT-a combination of three-dimensional radiotherapy (3D-CRT) and VMAT-were analyzed regarding planning target volume (PTV), dose coverage, and exposure to organs at risk (OAR).!##!Methods!#!Planning computed tomography scans were acquired in deep-inspiration breath-hold. A total of 520 treatment plans were calculated and evaluated for 40 patients, comprising six different H‑VMAT plans and a 3D-CRT plan as reference. H‑VMAT plans consisted of two treatment plans including 3D-CRT and VMAT. During H‑VMAT planning, the use of hard wedge filters (HWF) and beam energies were varied. The reference plans were planned with mixed beam energies and the inclusion/omission of HWF.!##!Results!#!Compared to the reference treatment plans, all H‑VMAT plans showed consistently better PTV dose coverage, conformity, and homogeneity. Additionally, OAR protection was significantly improved with several H‑VMAT combinations (p < 0.05). The comparison of different H‑VMAT combinations showed that inclusion of HWF in the base plan had a negative impact on PTV dose coverage, conformity, and OAR exposure. It also increased the planned monitor units and beam-on time. Advantages of using lower beam energies (6-MV photons) in both the base plan and in the VMAT supplementary dose were observed.!##!Conclusion!#!The H‑VMAT technique is an effective possibility for generating homogenous and conformal dose distributions. With the right choice of H‑VMAT combination, superior OAR protection is achieved compared to 3D-CRT.
1000 Sacherschließung
lokal Radiotherapy, Intensity-Modulated [MeSH]
lokal Humans [MeSH]
lokal Neoplasms, Second Primary [MeSH]
lokal Proton Therapy [MeSH]
lokal Literatur Kommentiert
lokal Radiotherapy Dosage [MeSH]
lokal Oncology
lokal Radiotherapy
lokal Esophageal Neoplasms [MeSH]
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/S3JhdXNlLCBNZWNodGhpbGQ=
1000 Hinweis
  • DeepGreen-ID: 1530c5716f7e459bafd712787209eb09 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6443198.rdf
1000 Erstellt am 2023-04-26T17:40:30.940+0200
1000 Erstellt von 322
1000 beschreibt frl:6443198
1000 Zuletzt bearbeitet 2023-10-14T04:12:45.422+0200
1000 Objekt bearb. Sat Oct 14 04:12:45 CEST 2023
1000 Vgl. frl:6443198
1000 Oai Id
  1. oai:frl.publisso.de:frl:6443198 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source