Download
s40618-021-01575-8.pdf 1,50MB
WeightNameValue
1000 Titel
  • A rapid point-of-care assay accurately measures vitamin D
1000 Autor/in
  1. Albrecht, K. |
  2. Lotz, J. |
  3. Frommer, L. |
  4. Lackner, K. J. |
  5. Kahaly, George J. |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-04-22
1000 Erschienen in
1000 Quellenangabe
  • 44(11):2485-2492
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s40618-021-01575-8 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8502163/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Purpose!#!Vitamin D (VitD) is a pleiotropic hormone with effects on a multitude of systems and metabolic pathways. Consequently, the relevance of a sufficiently high VitD serum level becomes self-evident.!##!Methods!#!A rapid immunofluorescence assay designed for the point-of-care measurement of serum VitD!##!Results!#!An overall linear correlation of r = 0.89 (Pearson, 95% CI 0.88-0.92, p < 0.01) between the point of care and the conventional reference assay was registered. Accuracy and precision were of special interest at cut-points (10 ng/ml [mean deviation 1.7 ng/ml, SD 1.98 ng/ml, SE 0.16 ng/ml], 12 ng/ml [MD 0.41, SD 1.89, SE 0.19] and 30 ng/ml [MD - 1.11, SD 3.89, SE 0.35]). Only a slight deviation was detected between the two assays when using fresh (r = 0.91, 95% CI 0.86-0.94, p < 0.01) and frozen serum samples (r = 0.86, 0.82-0.89, p < 0.01). Results remained steady when samples were frozen several times. Inter- and intra-assay validation according to the CLSI protocol as well as multiuser testing showed stable results.!##!Conclusion!#!This novel, innovative, and controlled study indicates that the evaluated rapid point of care VitD assay is reliable, accurate, and suited for clinical practice.
1000 Sacherschließung
lokal Point-of-Care Systems [MeSH]
lokal Vitamin D Deficiency/blood [MeSH]
lokal Chemiluminescence assay
lokal Humans [MeSH]
lokal Vitamin D serum levels
lokal Cholecalciferol/blood [MeSH]
lokal Dimensional Measurement Accuracy [MeSH]
lokal Point-of-care
lokal Luminescent Measurements/methods [MeSH]
lokal Vitamin D Deficiency/diagnosis [MeSH]
lokal Rapid On-site Evaluation [MeSH]
lokal Original Article
lokal Immunofluorescence assay
lokal Reproducibility of Results [MeSH]
lokal Cholecalciferol/analysis [MeSH]
lokal Fluorescent Antibody Technique/methods [MeSH]
lokal Rapid assay
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/QWxicmVjaHQsIEsu|https://frl.publisso.de/adhoc/uri/TG90eiwgSi4=|https://frl.publisso.de/adhoc/uri/RnJvbW1lciwgTC4=|https://frl.publisso.de/adhoc/uri/TGFja25lciwgSy4gSi4=|https://orcid.org/0000-0003-0441-430X
1000 Hinweis
  • DeepGreen-ID: 603060e436444ccbbed52f79131f58da ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
  1. A rapid point-of-care assay accurately measures vitamin D
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6445352.rdf
1000 Erstellt am 2023-04-28T10:02:54.331+0200
1000 Erstellt von 322
1000 beschreibt frl:6445352
1000 Zuletzt bearbeitet Fri Oct 20 15:15:55 CEST 2023
1000 Objekt bearb. Fri Oct 20 15:15:55 CEST 2023
1000 Vgl. frl:6445352
1000 Oai Id
  1. oai:frl.publisso.de:frl:6445352 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source