1000 Titel
  • An insert with less than spherical medial conformity causes a loss of passive internal rotation after calipered kinematically aligned TKA
1000 Autor/in
  1. Nedopil, Alexander |
  2. Shekhar, Adithya |
  3. Howell, Stephen M. |
  4. Hull, Maury L. |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-07-15
1000 Erschienen in
1000 Quellenangabe
  • 141(12):2287-2294
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00402-021-04054-0 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8595155/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Introduction!#!In total knee arthroplasty (TKA), the level of conformity, a medial stabilized (MS) implant, needs to restore native (i.e., healthy) knee kinematics without over-tensioning the flexion space when the surgeon chooses to retain the posterior cruciate ligament (PCL) is unknown. Whether an insert with a medial ball-in-socket conformity and lateral flat surface like the native knee or a less than spherical medial conformity restores higher and closer to native internal tibial rotation without anterior lift-off, an over-tension indicator, when implanted with calipered kinematic alignment (KA), is unknown.!##!Methods and materials!#!Two surgeons treated 21 patients with calipered KA and a PCL retaining MS implant. Validated verification checks that restore native tibial compartment forces in passive flexion without release of healthy ligaments were used to select the optimal insert thickness. A goniometer etched onto trial inserts with the ball-in-socket and the less than spherical medial conformity measured the tibial rotation relative to the femoral component at extension and 90° and 120° flexion. The surgeon recorded the incidence of anterior lift-off of the insert.!##!Results!#!The insert with the medial ball-in-socket and lateral flat surface restored more internal tibial rotation than the one with less than spherical medial conformity, with mean values of 19° vs. 17° from extension to 90° flexion (p < 0.01), and 23° vs. 20°-120° flexion (p < 0.002), respectively. There was no anterior lift-off of the insert at 90° and 120° flexion.!##!Conclusion!#!An MS insert with a medial ball-in-socket and lateral flat surface that matches the native knee's spherical conformity restores native tibial internal rotation when implanted with calipered KA and PCL retention without over-tensioning the flexion space.
1000 Sacherschließung
lokal Rotation
lokal Tibia/surgery [MeSH]
lokal Knee Arthroplasty
lokal Calipered
lokal Knee Prosthesis [MeSH]
lokal Humans [MeSH]
lokal Spherical
lokal Knee Joint/surgery [MeSH]
lokal Arthroplasty, Replacement, Knee [MeSH]
lokal Biomechanical Phenomena [MeSH]
lokal Insert
lokal Medial stabilized
lokal Total knee arthroplasty
lokal Range of Motion, Articular [MeSH]
lokal Total knee replacement
lokal Conforming
lokal Kinematic alignment
lokal New Technologies in Knee Arthroplasty
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-3655-158X|https://frl.publisso.de/adhoc/uri/U2hla2hhciwgQWRpdGh5YQ==|https://frl.publisso.de/adhoc/uri/SG93ZWxsLCBTdGVwaGVuIE0u|https://frl.publisso.de/adhoc/uri/SHVsbCwgTWF1cnkgTC4=
1000 Hinweis
  • DeepGreen-ID: 2bd1938d052645bfa458fa0edf94554d ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6447326.rdf
1000 Erstellt am 2023-04-28T15:44:22.044+0200
1000 Erstellt von 322
1000 beschreibt frl:6447326
1000 Zuletzt bearbeitet Fri Oct 20 20:27:35 CEST 2023
1000 Objekt bearb. Fri Oct 20 20:27:35 CEST 2023
1000 Vgl. frl:6447326
1000 Oai Id
  1. oai:frl.publisso.de:frl:6447326 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source