Download
s00402-021-04073-x.pdf 728,01KB
WeightNameValue
1000 Titel
  • Does the orientation of syndesmosis fixative device affect the immediate reduction of the distal tibiofibular joint?
1000 Autor/in
  1. Hennings, Robert |
  2. Spiegl, Ulrich |
  3. Fuchs, Carolin |
  4. Hepp, Pierre |
  5. Fakler, Johannes |
  6. Ahrberg, Annette |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-08-07
1000 Erschienen in
1000 Quellenangabe
  • 142(11):3213-3220
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00402-021-04073-x |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9522764/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Introduction!#!Incongruent stabilization of the distal tibiofibular joint (syndesmosis) results in poorer long-term outcome in malleolar fractures. The aim was to analyze whether the orientation of the syndesmotic stabilization would affect the immediate reduction imaged in computed tomography (CT).!##!Materials and methods!#!The syndesmotic congruity in 114 ankle fractures with stabilization of the syndesmosis were retrospectively analyzed in the post-operative bilateral CT scans. The incisura device angle (IDA) was defined and correlated with the side-to-side difference of Leporjärvi clear-space (ΔLCS), anterior tibiofibular distance (ΔantTFD) and Nault talar dome angle (ΔNTDA) regardless of the stabilization technique and separately for suture button system and syndesmotic screw. Asymmetric reduction was defined as ΔLCS > 2 mm and |ΔantTFD|> 2 mm.!##!Results!#!Regardless of the stabilization technique, no correlation between the IDA and the ΔLCS (r = 0.069), the ΔantTFD (r = 0.019) nor the ΔNTDA (r = 0.177) could be observed. There were no differences between suture button system and syndesmotic screw. Asymmetrical reduction was detected in 46% of the cases, while sagittal asymmetry was most common. No association was found between the orientation of stabilization device and occurrence of asymmetrical reduction (p > 0.05). The results of suture button system and syndesmotic screw were comparable in this respect (p > 0.05).!##!Conclusion!#!Poor correlation between the orientation of the stabilization device and the immediate post-operative congruity of the syndesmosis could be shown. In contrast to current literature, this study did not show difference of suture button system over syndesmotic screw in this regard. Careful adjustment of the fibula in anteroposterior orientation should be given special attention.
1000 Sacherschließung
lokal Ankle Joint/surgery [MeSH]
lokal Tibiofibular
lokal Trauma Surgery
lokal Ankle Injuries/diagnostic imaging [MeSH]
lokal Humans [MeSH]
lokal Ankle Fractures/diagnostic imaging [MeSH]
lokal Syndesmosis
lokal Retrospective Studies [MeSH]
lokal Ankle Injuries/surgery [MeSH]
lokal Ankle Joint/diagnostic imaging [MeSH]
lokal Bone Screws [MeSH]
lokal Syndesmotic screw
lokal Fixatives [MeSH]
lokal Suture button
lokal Fibula/surgery [MeSH]
lokal Fracture Fixation, Internal/methods [MeSH]
lokal Ankle Fractures/surgery [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-9936-5979|https://orcid.org/0000-0002-5179-4192|https://frl.publisso.de/adhoc/uri/RnVjaHMsIENhcm9saW4=|https://orcid.org/0000-0002-6510-2943|https://orcid.org/0000-0002-3769-534X|https://orcid.org/0000-0002-9083-4505
1000 Hinweis
  • DeepGreen-ID: bb8e2873f3b74057ab1009526203abdf ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6447336.rdf
1000 Erstellt am 2023-04-28T15:46:03.863+0200
1000 Erstellt von 322
1000 beschreibt frl:6447336
1000 Zuletzt bearbeitet Fri Oct 20 20:28:42 CEST 2023
1000 Objekt bearb. Fri Oct 20 20:28:42 CEST 2023
1000 Vgl. frl:6447336
1000 Oai Id
  1. oai:frl.publisso.de:frl:6447336 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source