Download
s00402-021-03919-8.pdf 1,25MB
WeightNameValue
1000 Titel
  • A standardized soft tissue release technique to lower the risk of greater trochanteric fractures for the anterior approach in total hip arthroplasty
1000 Autor/in
  1. List, Kilian |
  2. Springer, Bernhard |
  3. Jungwirth-Weinberger, Anna |
  4. Bechler, Ulrich |
  5. Kasparek, Maximillian F. |
  6. Boettner, Friedrich |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-05-05
1000 Erschienen in
1000 Quellenangabe
  • 142(11):3067-3073
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00402-021-03919-8 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9522704/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Introduction!#!The direct anterior approach (DAA) is suggested to accelerate postoperative recovery and decrease the dislocation risk after primary total hip arthroplasty (THA). However, exposure of the femur can be challenging. Insufficient exposure increases the risk for intraoperative femoral fracture.!##!Materials and methods!#!Of 435 consecutive anterior THA, the first 102 consecutive THA in 94 patients were treated with an external rotator tendon 'release-on-demand' (RoD). The following 311 consecutive patients (333 THA) underwent routine release of the conjoint tendon (CTR) of its bony insertion on the greater trochanter only. Retrospective analysis recorded trochanteric fractures, intraoperative calcar fractures, postoperative periprosthetic fractures, stem subsidence, ossifications, and dislocations.!##!Results!#!Three (2.9%) fractures of the greater trochanter were recorded in the RoD group, but no (0.0%) fractures occurred in the CTR group (p = 0.002). There was no significant difference in the occurrence of intraoperative calcar fractures (0% (RoD) vs. 1.2% (CTR), p = 0.267), postoperative periprosthetic fractures (0% (RoD) vs. 0.3% (CTR), p = 0.560), stem subsidence (2.0% (RoD) vs. 1.2% (CTR), p = 0.565) or ossifications (2.9% (RoD) vs. 1.6% (CTR), p = 0.344) between these groups. There were no dislocations within a minimum 12 months follow-up period.!##!Conclusion!#!The routine release of the conjoined tendon (CTR group) decreases the shear forces on the tip of the greater trochanter during DAA THA and eliminates the risk of greater trochanter fractures. The routine release of the conjoined tendon did not increase the risk of postoperative dislocations.
1000 Sacherschließung
lokal Hip Prosthesis/adverse effects [MeSH]
lokal Intraoperative Complications/etiology [MeSH]
lokal Humans [MeSH]
lokal DAA
lokal Retrospective Studies [MeSH]
lokal Periprosthetic Fractures/surgery [MeSH]
lokal Hip Fractures/etiology [MeSH]
lokal Femur/surgery [MeSH]
lokal Joint Dislocations/surgery [MeSH]
lokal Complications
lokal Surgical technique
lokal Arthroplasty, Replacement, Hip/methods [MeSH]
lokal Arthroplasty, Replacement, Hip/adverse effects [MeSH]
lokal Orthopaedic Surgery
lokal Minimal invasive surgery
lokal Hip Fractures/surgery [MeSH]
lokal Trochanteric fracture
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-9965-1799|https://frl.publisso.de/adhoc/uri/U3ByaW5nZXIsIEJlcm5oYXJk|https://frl.publisso.de/adhoc/uri/SnVuZ3dpcnRoLVdlaW5iZXJnZXIsIEFubmE=|https://frl.publisso.de/adhoc/uri/QmVjaGxlciwgVWxyaWNo|https://frl.publisso.de/adhoc/uri/S2FzcGFyZWssIE1heGltaWxsaWFuIEYu|https://frl.publisso.de/adhoc/uri/Qm9ldHRuZXIsIEZyaWVkcmljaA==
1000 Hinweis
  • DeepGreen-ID: 221fb174f8cc44cb8152e183e4d0f968 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6447366.rdf
1000 Erstellt am 2023-04-28T15:51:09.907+0200
1000 Erstellt von 322
1000 beschreibt frl:6447366
1000 Zuletzt bearbeitet 2023-10-20T20:31:40.508+0200
1000 Objekt bearb. Fri Oct 20 20:31:40 CEST 2023
1000 Vgl. frl:6447366
1000 Oai Id
  1. oai:frl.publisso.de:frl:6447366 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source