Download
s00167-021-06840-0.pdf 1,82MB
WeightNameValue
1000 Titel
  • More passive internal tibial rotation with posterior cruciate ligament retention than with excision in a medial pivot TKA implanted with unrestricted caliper verified kinematic alignment
1000 Autor/in
  1. Nedopil, Alexander |
  2. Howell, Stephen M. |
  3. Hull, Maury L. |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-12-18
1000 Erschienen in
1000 Quellenangabe
  • 31(3):852-860
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00167-021-06840-0 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958185/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Purpose!#!Excision of the posterior cruciate ligament (PCL) is recommended when implanting a medial pivot (MP) total knee arthroplasty (TKA) to reduce the risk of limiting flexion by over-tensioning the flexion space. The present study determined whether PCL retention (1) limits internal tibial rotation and (2) causes anterior lift-off of the insert in 90° flexion after implantation of an MP design with unrestricted caliper verified kinematic alignment (KA).!##!Methods!#!Four surgeons implanted an MP TKA design with medial ball-in-socket and lateral flat tibial insert in ten fresh-frozen cadaveric knees. Before and after PCL excision, trial inserts with medial goniometric markings measured the angular I-E tibial orientation relative to the trial femoral component's medial condyle in extension and at 90° flexion, and the surgeon recorded the occurrence of anterior lift-off of the insert at 90° flexion.!##!Results!#!PCL retention resulted in greater internal tibial rotation than PCL excision, with mean values of 15° vs 7° degrees from maximum extension to 90° flexion, respectively (p < 0.0007). At 90° flexion, no TKAs with PCL retention and one TKA with PCL excision had anterior lift-off of the insert (N.S.).!##!Conclusions!#!This preliminary study of ten cadaveric knees showed that PCL retention restored more passive internal tibial rotation than PCL excision with a negligible risk of anterior lift-off. However, in vivo analysis from multiple authors with a larger sample size is required to recommend PCL retention with an MP TKA design implanted with unrestricted caliper verified KA.
1000 Sacherschließung
lokal Tibia/surgery [MeSH]
lokal Calipered
lokal Knee Prosthesis [MeSH]
lokal Insert thickness
lokal Humans [MeSH]
lokal Posterior cruciate ligament
lokal Knee Joint/surgery [MeSH]
lokal Biomechanical Phenomena [MeSH]
lokal Tibial rotation
lokal Total knee arthroplasty
lokal Knee
lokal Posterior Cruciate Ligament/surgery [MeSH]
lokal Range of Motion, Articular [MeSH]
lokal Total knee replacement
lokal Cadaver [MeSH]
lokal Arthroplasty, Replacement, Knee/methods [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-3655-158X|https://frl.publisso.de/adhoc/uri/SG93ZWxsLCBTdGVwaGVuIE0u|https://frl.publisso.de/adhoc/uri/SHVsbCwgTWF1cnkgTC4=
1000 Hinweis
  • DeepGreen-ID: 99018e2f7f5e40dca4ef5c1022749a88 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6448031.rdf
1000 Erstellt am 2023-05-03T17:11:06.815+0200
1000 Erstellt von 322
1000 beschreibt frl:6448031
1000 Zuletzt bearbeitet Fri Oct 20 21:49:04 CEST 2023
1000 Objekt bearb. Fri Oct 20 21:49:04 CEST 2023
1000 Vgl. frl:6448031
1000 Oai Id
  1. oai:frl.publisso.de:frl:6448031 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source