Download
s00167-021-06697-3.pdf 685,74KB
WeightNameValue
1000 Titel
  • Interobserver reliability is higher for assessments with 3D software-generated models than with conventional MRI images in the classification of trochlear dysplasia
1000 Autor/in
  1. Fuchs, Andreas |
  2. Feucht, Matthias J. |
  3. Dickschas, Jörg |
  4. Frings, Jannik |
  5. Siegel, Markus |
  6. Yilmaz, Tayfun |
  7. Schmal, Hagen |
  8. Izadpanah, Kaywan |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-08-22
1000 Erschienen in
1000 Quellenangabe
  • 30(5):1654-1660
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00167-021-06697-3 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9033701/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Purpose!#!Trochlear dysplasia is a significant risk factor for patellofemoral instability. The severity of trochlear dysplasia is commonly evaluated based on the Dejour classification in axial MRI slices. However, this often leads to heterogeneous assessments. A software to generate MRI-based 3D models of the knee was developed to ensure more standardized visualization of knee structures. The purpose of this study was to assess the intra- and interobserver agreements of 2D axial MRI slices and an MRI-based 3D software generated model in classification of trochlear dysplasia as described by Dejour.!##!Methods!#!Four investigators independently assessed 38 axial MRI scans for trochlear dysplasia. Analysis was made according to Dejour's 4 grade classification as well as differentiating between 2 grades: low-grade (types A + B) and high-grade trochlear dysplasia (types C + D). Assessments were repeated following a one-week interval. The inter- and intraobserver agreement was determined using Cohen's kappa (κ) and Fleiss kappa statistic (κ). In addition, the proportion of observed agreement (po) was calculated for assessment of intraobserver agreement.!##!Results!#!The assessment of the intraobserver reliability with regard to the Dejour-classification showed moderate agreement values both in the 2D (κ = 0.59 ± 0.08 SD) and in the 3D analysis (κ = 0.57 ± 0.08 SD). Considering the 2-grade classification, the 2D (κ = 0.62 ± 0.12 SD) and 3D analysis (κ = 0.61 ± 0.19 SD) each showed good intraobserver matches. The analysis of the interobserver reliability also showed moderate agreement values with differences in the subgroups (2D vs. 3D). The 2D evaluation showed correspondences of κ = 0.48 (Dejour) and κ = 0.46 (high / low). In the assessment based on the 3D models, correspondence values of κ = 0.53 (Dejour) and κ = 0.59 (high / low) were documented.!##!Conclusion!#!Overall, moderate-to-good agreement values were found in all groups. The analysis of the intraobserver reliability showed no relevant differences between 2 and 3D representation, but better agreement values were found in the 2-degree classification. In the analysis of interobserver reliability, better agreement values were found in the 3D compared to the 2D representation. The clinical relevance of this study lies in the superiority of the 3D representation in the assessment of trochlear dysplasia, which is relevant for future analytical procedures as well as surgical planning.!##!Level of evidence!#!Level II.
1000 Sacherschließung
lokal Knee Joint [MeSH]
lokal Magnetic Resonance Imaging [MeSH]
lokal Knee
lokal Reproducibility of Results [MeSH]
lokal 3D model
lokal Patellar instability
lokal Humans [MeSH]
lokal Software [MeSH]
lokal Joint Instability/surgery [MeSH]
lokal Trochlear dysplasia
lokal Dejour
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-0816-8188|https://frl.publisso.de/adhoc/uri/RmV1Y2h0LCBNYXR0aGlhcyBKLg==|https://frl.publisso.de/adhoc/uri/RGlja3NjaGFzLCBKw7ZyZw==|https://frl.publisso.de/adhoc/uri/RnJpbmdzLCBKYW5uaWs=|https://frl.publisso.de/adhoc/uri/U2llZ2VsLCBNYXJrdXM=|https://frl.publisso.de/adhoc/uri/WWlsbWF6LCBUYXlmdW4=|https://frl.publisso.de/adhoc/uri/U2NobWFsLCBIYWdlbg==|https://frl.publisso.de/adhoc/uri/SXphZHBhbmFoLCBLYXl3YW4=
1000 Hinweis
  • DeepGreen-ID: e03f61dffd2c485b98ab6b51d7887d37 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6448035.rdf
1000 Erstellt am 2023-05-03T17:11:54.008+0200
1000 Erstellt von 322
1000 beschreibt frl:6448035
1000 Zuletzt bearbeitet Fri Oct 20 21:49:36 CEST 2023
1000 Objekt bearb. Fri Oct 20 21:49:36 CEST 2023
1000 Vgl. frl:6448035
1000 Oai Id
  1. oai:frl.publisso.de:frl:6448035 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source