  • Comparison of two resilient attachment systems for implant-/mucosa-supported overdentures with a PEKK framework: a clinical pilot study
1000 Autor/in
  1. Dörsam, Istabrak |
  2. Hombach, Anastasia |
  3. Bourauel, Christoph |
  4. Stark, Helmut |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-12-21
1000 Erschienen in
1000 Quellenangabe
  • 26(4):3707-3719
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00784-021-04342-4 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8979906/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Objectives!#!The aim of the study was to determine differences between Locator and CM LOC attachment systems regarding patient satisfaction and wear of the abutments and their inserts. Plaque accumulation onto the polyetherketoneketone (PEKK) framework and polymethylmethacrylate (PMMA) was investigated for the implant-supported overdentures.!##!Methods!#!Seventeen edentulous patients were randomised to receive either Locator or CM LOC system for the first year. The total number of implants was 53. After the randomisation, 25 implants received Locator system, and 28 implants received CM LOC system in the first year. After a period of 12 months, the attachment system was exchanged from either Locator to CM LOC or vice versa. Oral Health Impact Profile (OHIP-14) questionnaires were used to evaluate patient satisfaction, chewing comfort, and pressure lesions. Prosthesis hygiene on the PMMA and PEKK surfaces was evaluated by using Stark plaque index. After the exchange of the abutments, they were stored until the end of the 24 months, and the surface wear of the abutments was analysed using a scanning electron microscope.!##!Results!#!Three patients (10 implants) died shortly before the end of the first year. Two patients (7 implants) received only Locator system since CM LOC was not indictable for their implant system. Patient's satisfaction was increased when the attachment system was changed from Locator to CM LOC after 12 months of wearing time. Chewing ability and comfort were increased when the attachment system was changed from CM LOC to Locator after 12-month wearing time. There was no influence of the change of the attachment system on pressure lesions. The observed plaque accumulation was higher on the PMMA than on the PEKK surface. For the 8 investigated Locator abutments, the wear was within low and middle level. For the 28 investigated CM LOC abutments, the wear was within middle and high level for the terminal implants and between low and middle for the central implants (for patients who received 4 implants).!##!Conclusions!#!Patient's satisfaction and wearing comfort can be improved with implant-supported overdentures with CM LOC abutments in comparison to Locator. There was no clear difference between both attachment systems concerning the chewing ability of the patients. Plaque accumulation was observed on both attachment systems in different areas. Plaque accumulation on PEKK surface was less than on PMMA surface.!##!Clinical relevance!#!The CM LOC attachment system offers stable and comfortable wearing conditions for implant-supported overdentures. The use of PEKK as a framework material could reduce the incidence of pressure lesions.
1000 Sacherschließung
lokal Benzophenones [MeSH]
lokal Denture, Overlay [MeSH]
lokal Dental Implants [MeSH]
lokal Humans [MeSH]
lokal Jaw, Edentulous [MeSH]
lokal Mandible [MeSH]
lokal Plaque accumulation
lokal Original Article
lokal Dental Prosthesis, Implant-Supported [MeSH]
lokal Polymers [MeSH]
lokal Pilot Projects [MeSH]
lokal Denture Retention [MeSH]
lokal PEKK
lokal Attachment system
lokal Overdenture
lokal Wear
lokal Mucous Membrane [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-4012-6279|https://frl.publisso.de/adhoc/uri/SG9tYmFjaCwgQW5hc3Rhc2lh|https://frl.publisso.de/adhoc/uri/Qm91cmF1ZWwsIENocmlzdG9waA==|https://frl.publisso.de/adhoc/uri/U3RhcmssIEhlbG11dA==
1000 Hinweis
  • DeepGreen-ID: 3f9bf3d82ee94515ac82ccd0513b6da6 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6449122.rdf
1000 Erstellt am 2023-05-04T11:20:58.618+0200
1000 Erstellt von 322
1000 beschreibt frl:6449122
1000 Zuletzt bearbeitet Sat Oct 21 00:24:45 CEST 2023
1000 Objekt bearb. Sat Oct 21 00:24:45 CEST 2023
1000 Vgl. frl:6449122
1000 Oai Id
  1. oai:frl.publisso.de:frl:6449122 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source