Download
s00701-021-04807-1.pdf 1,05MB
WeightNameValue
1000 Titel
  • Frameless x-ray-based lead re-implantation after partial hardware removal of deep brain stimulation system with preservation of intracerebral trajectories
1000 Autor/in
  1. Malinova, Vesna |
  2. Jaskólski, Dariusz J. |
  3. Wójcik, Rafal |
  4. Mielke, Dorothee |
  5. Rohde, Veit |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-03-23
1000 Erschienen in
1000 Quellenangabe
  • 163(7):1873-1878
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00701-021-04807-1 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8195963/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!Deep brain stimulation (DBS) is an established treatment for patients with medical refractory movement disorders with continuously increasing use also in other neurological and psychiatric diseases. Early and late complications can lead to revision surgeries with partial or complete DBS-system removal. In this study, we aimed to report on our experience with a frameless x-ray-based lead re-implantation technique after partial hardware removal or dysfunction of DBS-system, allowing the preservation of intracerebral trajectories.!##!Methods!#!We describe a surgical procedure with complete implant removal due to infection except for the intracranial part of the electrode and with non-stereotactic electrode re-implantation. A retrospective analysis of a patient series treated using this technique was performed and the surgical outcome was evaluated including radiological and clinical parameters.!##!Results!#!A total of 8 DBS-patients with lead re-implantation using the frameless x-ray-based method were enrolled in the study. A revision of 14 leads was performed, whereof a successful lead re-implantation could be achieved without any problems in 10 leads (71%). In two patients (one patient with dystonia and one patient with tremor), the procedure was not successful, so we placed both leads frame-based stereotactically.!##!Conclusions!#!The described x-ray-based technique allows a reliable frameless electrode re-implantation after infection and electrode dysfunction and might represent an efficient alternative to frame-based procedures for lead revision making the preservation of intracerebral trajectories possible.
1000 Sacherschließung
lokal Female [MeSH]
lokal Aged [MeSH]
lokal Adult [MeSH]
lokal Humans [MeSH]
lokal Electrodes, Implanted [MeSH]
lokal Stereotaxic Techniques [MeSH]
lokal Retrospective Studies [MeSH]
lokal X-Rays [MeSH]
lokal Middle Aged [MeSH]
lokal Technical Note - Functional Neurosurgery - Other
lokal Functional Neurosurgery – Other
lokal Male [MeSH]
lokal Deep Brain Stimulation [MeSH]
lokal Hardware dysfunction
lokal Hardware infection
lokal Frameless lead replacement
lokal Deep brain stimulation
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-0062-7490|https://frl.publisso.de/adhoc/uri/SmFza8OzbHNraSwgRGFyaXVzeiBKLg==|https://frl.publisso.de/adhoc/uri/V8OzamNpaywgUmFmYWw=|https://frl.publisso.de/adhoc/uri/TWllbGtlLCBEb3JvdGhlZQ==|https://frl.publisso.de/adhoc/uri/Um9oZGUsIFZlaXQ=
1000 Hinweis
  • DeepGreen-ID: 556793fc133a4a83955dbf684bcd8af6 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6449270.rdf
1000 Erstellt am 2023-05-04T13:44:18.176+0200
1000 Erstellt von 322
1000 beschreibt frl:6449270
1000 Zuletzt bearbeitet Sat Oct 21 00:49:55 CEST 2023
1000 Objekt bearb. Sat Oct 21 00:49:55 CEST 2023
1000 Vgl. frl:6449270
1000 Oai Id
  1. oai:frl.publisso.de:frl:6449270 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source