1000 Abstract/Summary
  • Background and aim!#!In the past, increased latencies of the blue-on-yellow pattern visually evoked potentials (BY-VEP), which predominantly originate in the koniocellular pathway, have proven to be a sensitive biomarker for early glaucoma. However, a complex experimental setup based on an optical bench was necessary to obtain these measurements because computer screens lack sufficient temporal, spatial, spectral, and luminance resolution. Here, we evaluated the diagnostic value of a novel setup based on a commercially available video projector.!##!Methods!#!BY-VEPs were recorded in 126 participants (42 healthy control participants, 12 patients with ocular hypertension, 17 with 'preperimetric' glaucoma, and 55 with perimetric glaucoma). Stimuli were created with a video projector (DLP technology) by rear projection of a blue checkerboard pattern (460 nm) for 200 ms (onset) superimposed on a bright yellow background (574 nm), followed by an offset interval where only the background was active. Thus, predominantly S-cones were stimulated while L- and M-cone responses were suppressed by light adaptation. Times of stimulus onset to VEP onset-trough (N-peak time) and offset-peak (P-peak time) were analyzed after age-correction based on linear regression in the normal participants.!##!Results!#!The resulting BY-VEPs were quite similar to those obtained in the past with the optical bench: pattern-onset generated a negative deflection of the VEP, whereas the offset-response was dominated by a positive component. N-peak times were significantly increased in glaucoma patients (preperimetric 136.1 ± 10 ms, p < 0.05; perimetric 153.1 ± 17.8 ms, p < 0.001) compared with normal participants (123.6 ± 7.7 ms). Furthermore, they were significantly correlated with disease severity as determined by visual field losses retinal nerve fiber thinning (Spearman R = -0.7, p < 0.001).!##!Conclusions!#!Video projectors can be used to create optical stimuli with high temporal and spatial resolution, thus potentially enabling sophisticated electrophysiological measurements in clinical practice. BY-VEPs based on such a projector had a high diagnostic value for detection of early glaucoma. Registration of study Registration site: www.!##!Clinicaltrials!#!gov Trial registration number: NCT00494923.
1000 Sacherschließung
lokal Glaucoma/diagnosis [MeSH]
lokal Evoked Potentials, Visual [MeSH]
lokal Visual Field Tests [MeSH]
lokal Humans [MeSH]
lokal Onset–offset VEP
lokal Glaucoma
lokal Blue–yellow VEP
lokal Glaucoma, Open-Angle/diagnosis [MeSH]
lokal Ocular Hypertension [MeSH]
lokal Basic Science
lokal Projector-stimulation
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/RHVzc2FuIE1vbGlub3MsIExhdXJh|https://orcid.org/0000-0002-0408-8981|https://orcid.org/0000-0002-6294-0730|https://orcid.org/0000-0002-9293-7380|https://orcid.org/0000-0002-2590-1169
1000 Hinweis
  • DeepGreen-ID: 1a7a6722016d4f53914f69d31b665de7 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
  1. Blue–Yellow VEP with Projector-Stimulation in Glaucoma
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6450108.rdf
1000 Erstellt am 2023-05-09T11:14:55.916+0200
1000 Erstellt von 322
1000 beschreibt frl:6450108
1000 Zuletzt bearbeitet 2023-10-21T02:47:09.943+0200
1000 Objekt bearb. Sat Oct 21 02:47:09 CEST 2023
1000 Vgl. frl:6450108
1000 Oai Id
  1. oai:frl.publisso.de:frl:6450108 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source