Download
s00417-021-05374-y.pdf 1,32MB
WeightNameValue
1000 Titel
  • Measurement of the retinal venous pressure with a new instrument in healthy subjects
1000 Autor/in
  1. Stodtmeister, Richard |
  2. Wetzk, Emilie |
  3. Herber, Robert |
  4. Pillunat, Karin R. |
  5. Pillunat, Lutz E. |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-09-09
1000 Erschienen in
1000 Quellenangabe
  • 260(4):1237-1244
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00417-021-05374-y |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8913447/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!The retinal venous pressure (RVP) is a determining factor for the blood supply of the retina as well as the optic nerve head and until recently has been measured by contact lens dynamometry (CLD). A new method has been developed, potentially offering better acceptance. The applicability and the results of both methods were compared.!##!Methods!#!The type of this study is cross sectional. The subjects were 36 healthy volunteers, age 26 ± 5 years (mean ± s). Tonometry: rebound tonometer (RT) (iCare). The measurements were performed during an increase in airway pressure of 20 mmHg (Valsalva manoeuvre). Principle of RVP measurement: the central retinal vein (CRV) is observed during an increase of intraocular pressure (IOP) and at the start of pulsation, which corresponds with the RVP. Two different instruments for the IOP enhancement where used: contact lens dynamometry and the new instrument, IOPstim.!##!Principle!#!a deflated balloon of 8 mm diameter-placed on the sclera laterally of the cornea-is filled with air. As soon as a venous pulsation occurs, filling is stopped and the IOP is measured, equalling the RVP. Examination procedure: randomization of the sequence: CLD or IOPstim, IOP, mydriasis, IOP three single measurements (SM) of the IOP with RT or of the pressure increase with CLD at an airway pressure of 20 mmHg, 5 min break, IOP, and three SM using the second method at equal pressure (20 mmHg).!##!Results!#!Spontaneous pulsation of the CRV was present in all 36 subjects. Pressures are given in mmHg. IOP in mydriasis 15.6 ± 3.3 (m ± s). Median RVP (MRVP)) of the three SM: CLD/IOPstim, 37.7 ± 5.2/24.7 ± 4.8 (t test: p < 0.001). Range of SM: 3.2 ± 1.8/2.9 ± 1.3 (t test: p = 0.36). Intraclass correlation coefficient (ICC) of SM: 0.88/0.83. ANOVA in SM: p = 0.48/0.08. MRVP CLD minus MRVP IOPstim: 13.0 ± 5.6. Ratio MRVP CLD/MRVP IOPstim: 1.56 ± 3.1. Cooperation and agreeability were slightly better with the IOPstim.!##!Conclusion!#!This first study with the IOPstim in humans was deliberately performed in healthy volunteers using Valsalva conditions. As demonstrated by ICC and ANOVA, reproducible SM can be obtained by both methods and the range of the SM does not differ greatly. The higher MRVP in CLD could be explained by the different directions of the force vectors.
1000 Sacherschließung
lokal Dynamometry
lokal Venous pressure
lokal Adult [MeSH]
lokal Humans [MeSH]
lokal Retina
lokal Retina [MeSH]
lokal Venous Pressure/physiology [MeSH]
lokal Cross-Sectional Studies [MeSH]
lokal Glaucoma
lokal Valsalva manoeuvre
lokal Reproducibility of Results [MeSH]
lokal Healthy Volunteers [MeSH]
lokal Young Adult [MeSH]
lokal Intraocular Pressure [MeSH]
lokal Tonometry, Ocular/methods [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-8689-2913|https://frl.publisso.de/adhoc/uri/V2V0emssIEVtaWxpZQ==|https://frl.publisso.de/adhoc/uri/SGVyYmVyLCBSb2JlcnQ=|https://frl.publisso.de/adhoc/uri/UGlsbHVuYXQsIEthcmluIFIu|https://frl.publisso.de/adhoc/uri/UGlsbHVuYXQsIEx1dHogRS4=
1000 Hinweis
  • DeepGreen-ID: f034fd2a85bf4468b64cf41cb4560f37 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6450118.rdf
1000 Erstellt am 2023-05-09T11:17:06.875+0200
1000 Erstellt von 322
1000 beschreibt frl:6450118
1000 Zuletzt bearbeitet 2023-10-21T02:48:30.878+0200
1000 Objekt bearb. Sat Oct 21 02:48:30 CEST 2023
1000 Vgl. frl:6450118
1000 Oai Id
  1. oai:frl.publisso.de:frl:6450118 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source