Download
s00392-021-01961-5.pdf 1,21MB
WeightNameValue
1000 Titel
  • Impact of asymmetric tethering on outcomes after edge-to-edge mitral valve repair for secondary mitral regurgitation
1000 Autor/in
  1. Stolz, Lukas |
  2. Orban, Mathias |
  3. Braun, Daniel |
  4. Doldi, Philipp |
  5. Orban, Martin |
  6. Stark, Konstantin |
  7. Mehr, Michael |
  8. Steffen, Julius |
  9. Löw, Kornelia |
  10. Hagl, Christian |
  11. Massberg, Steffen |
  12. Näbauer, Michael |
  13. Hausleiter, Jörg |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-11-16
1000 Erschienen in
1000 Quellenangabe
  • 111(8):869-880
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00392-021-01961-5 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9334427/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!The impact of postero-anterior and medio-lateral mitral valve (MV) tethering patterns on outcomes in patients undergoing transcatheter edge-to-edge repair (M-TEER) for secondary mitral regurgitation (SMR) is unknown.!##!Methods!#!The ratio of the posterior to anterior MV leaflet angle (PLA/ALA) in MV segment 2 was defined as postero-anterior tethering asymmetry. Medio-lateral tethering asymmetry was assessed as the ratio of the medial (segment 3) to lateral (segment 1) MV tenting area. We used receiver-operating characteristics and a Cox regression model to identify cut-off values of asymmetric anteroposterior and medio-lateral tethering for prediction of 2 year all-cause mortality after TMVR.!##!Results!#!Among 178 SMR patients, postero-anterior tethering was asymmetric in 67 patients (37.9%, PLA/ALA ratio > 1.54). Asymmetric medio-lateral tethering (tenting area ratio > 1.49) was observed in 49 patients (27.5%). M-TEER reduced MR to ≤ 2 + in 92.1% of patients; MR reduction was less effective in the presence of asymmetric postero-anterior tethering (p = 0.02). A multivariable Cox regression model identified both types of asymmetric MV tethering to be associated with increased all-cause 2-year mortality (postero-anterior tethering asymmetry: HR = 2.77, CI 1.43-5.38; medio-lateral tethering asymmetry: HR = 2.90, CI 1.54-5.45; p < 0.01).!##!Conclusions!#!Asymmetric postero-anterior and medio-lateral MV tethering patterns are associated with increased 2-year mortality in patients undergoing M-TEER for SMR. A detailed echocardiographic analysis of MV anatomy may help to identify patients who profit most from M-TEER.
1000 Sacherschließung
lokal Asymmetric tethering
lokal Mitral Valve/diagnostic imaging [MeSH]
lokal Secondary mitral regurgitation
lokal Polyesters [MeSH]
lokal Heart failure
lokal Mitral Valve Insufficiency/diagnosis [MeSH]
lokal Mitral Valve Insufficiency/surgery [MeSH]
lokal Humans [MeSH]
lokal Treatment Outcome [MeSH]
lokal MitraClip
lokal Heart Valve Prosthesis Implantation/adverse effects [MeSH]
lokal Original Paper
lokal Transcatheter mitral valve edge-to-edge repair
lokal Mitral Valve Insufficiency/etiology [MeSH]
lokal Mitral Valve/surgery [MeSH]
lokal Echocardiography, Transesophageal [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-1362-1493|https://frl.publisso.de/adhoc/uri/T3JiYW4sIE1hdGhpYXM=|https://frl.publisso.de/adhoc/uri/QnJhdW4sIERhbmllbA==|https://frl.publisso.de/adhoc/uri/RG9sZGksIFBoaWxpcHA=|https://frl.publisso.de/adhoc/uri/T3JiYW4sIE1hcnRpbg==|https://frl.publisso.de/adhoc/uri/U3RhcmssIEtvbnN0YW50aW4=|https://frl.publisso.de/adhoc/uri/TWVociwgTWljaGFlbA==|https://frl.publisso.de/adhoc/uri/U3RlZmZlbiwgSnVsaXVz|https://frl.publisso.de/adhoc/uri/TMO2dywgS29ybmVsaWE=|https://frl.publisso.de/adhoc/uri/SGFnbCwgQ2hyaXN0aWFu|https://frl.publisso.de/adhoc/uri/TWFzc2JlcmcsIFN0ZWZmZW4=|https://frl.publisso.de/adhoc/uri/TsOkYmF1ZXIsIE1pY2hhZWw=|https://frl.publisso.de/adhoc/uri/SGF1c2xlaXRlciwgSsO2cmc=
1000 Hinweis
  • DeepGreen-ID: b65dcadc8a2545119cce2cb92f765656 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6450850.rdf
1000 Erstellt am 2023-05-11T11:15:52.312+0200
1000 Erstellt von 322
1000 beschreibt frl:6450850
1000 Zuletzt bearbeitet 2023-10-20T10:20:29.931+0200
1000 Objekt bearb. Fri Oct 20 10:20:29 CEST 2023
1000 Vgl. frl:6450850
1000 Oai Id
  1. oai:frl.publisso.de:frl:6450850 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source