  • Threshold-dependent iodine imaging and spectral separation in a whole-body photon-counting CT system
1000 Autor/in
  1. Sawall, Stefan |
  2. Klein, L. |
  3. Wehrse, E. |
  4. Rotkopf, L. T. |
  5. Amato, C. |
  6. Maier, J. |
  7. Schlemmer, H.-P. |
  8. Ziener, C. H. |
  9. Heinze, S. |
  10. Kachelrieß, M. |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-03-13
1000 Erschienen in
1000 Quellenangabe
  • 31(9):6631-6639
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00330-021-07786-0 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8379121/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Objective!#!To evaluate the dual-energy (DE) performance and spectral separation with respect to iodine imaging in a photon-counting CT (PCCT) and compare it to dual-source CT (DSCT) DE imaging.!##!Methods!#!A semi-anthropomorphic phantom extendable with fat rings equipped with iodine vials is measured in an experimental PCCT. The system comprises a PC detector with two energy bins (20 keV, T) and (T, eU) with threshold T and tube voltage U. Measurements using the PCCT are performed at all available tube voltages (80 to 140 kV) and threshold settings (50-90 keV). Further measurements are performed using a conventional energy-integrating DSCT. Spectral separation is quantified as the relative contrast media ratio R between the energy bins and low/high images. Image noise and dose-normalized contrast-to-noise ratio (CNRD) are evaluated in resulting iodine images. All results are validated in a post-mortem angiography study.!##!Results!#!R of the PC detector varies between 1.2 and 2.6 and increases with higher thresholds and higher tube voltage. Reference R of the EI DSCT is found as 2.20 on average overall phantoms. Maximum CNRD in iodine images is found for T = 60/65/70/70 keV for 80/100/120/140 kV. The highest CNRD of the PCCT is obtained using 140 kV and is decreasing with decreasing tube voltage. All results could be confirmed in the post-mortem angiography study.!##!Conclusion!#!Intrinsically acquired DE data are able to provide iodine images similar to conventional DSCT. However, PCCT thresholds should be chosen with respect to tube voltage to maximize image quality in retrospectively derived image sets.!##!Key points!#!• Photon-counting CT allows for the computation of iodine images with similar quality compared to conventional dual-source dual-energy CT. • Thresholds should be chosen as a function of the tube voltage to maximize iodine contrast-to-noise ratio in derived image sets. • Image quality of retrospectively computed image sets can be maximized using optimized threshold settings.
1000 Sacherschließung
lokal Tomography, X-Ray Computed [MeSH]
lokal Photons [MeSH]
lokal Iodine
lokal Humans [MeSH]
lokal Phantoms, Imaging [MeSH]
lokal Angiography
lokal Retrospective Studies [MeSH]
lokal Tomography, X-ray computed
lokal Computed Tomography
lokal Iodine [MeSH]
lokal Phantoms, imaging
lokal Contrast media
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0001-8895-7541|https://frl.publisso.de/adhoc/uri/S2xlaW4sIEwu|https://frl.publisso.de/adhoc/uri/V2VocnNlLCBFLg==|https://frl.publisso.de/adhoc/uri/Um90a29wZiwgTC4gVC4=|https://frl.publisso.de/adhoc/uri/QW1hdG8sIEMu|https://frl.publisso.de/adhoc/uri/TWFpZXIsIEou|https://frl.publisso.de/adhoc/uri/U2NobGVtbWVyLCBILi1QLg==|https://frl.publisso.de/adhoc/uri/WmllbmVyLCBDLiBILg==|https://frl.publisso.de/adhoc/uri/SGVpbnplLCBTLg==|https://frl.publisso.de/adhoc/uri/S2FjaGVscmllw58sIE0u
1000 Hinweis
  • DeepGreen-ID: 2309292e00994c60a3a62e3e9ffdbb58 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6451265.rdf
1000 Erstellt am 2023-05-11T12:48:27.130+0200
1000 Erstellt von 322
1000 beschreibt frl:6451265
1000 Zuletzt bearbeitet Sat Oct 21 04:36:53 CEST 2023
1000 Objekt bearb. Sat Oct 21 04:36:53 CEST 2023
1000 Vgl. frl:6451265
1000 Oai Id
  1. oai:frl.publisso.de:frl:6451265 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source