Download
s00330-020-07677-w.pdf 764,35KB
WeightNameValue
1000 Titel
  • Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective
1000 Autor/in
  1. Gassert, Felix |
  2. Schacky, Claudio E. |
  3. Müller-Leisse, Christina |
  4. Gassert, Florian T. |
  5. Pahn, Gregor |
  6. Laugwitz, Karl-Ludwig |
  7. Makowski, Marcus R. |
  8. Nadjiri, Jonathan |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-01-20
1000 Erschienen in
1000 Quellenangabe
  • 31(8):6193-6199
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00330-020-07677-w |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8270810/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Objective!#!Determination of coronary artery calcium scoring (CACS) in non-contrast computed tomography (CT) images has been shown to be an important prognostic factor in coronary artery disease (CAD). The objective of this study was to evaluate the accuracy of CACS from virtual non-contrast (VNC) imaging generated from spectral data in comparison to standard (true) non-contrast (TNC) imaging in a representative patient cohort with clinically approved software.!##!Methods!#!One hundred three patients referred to coronary CTA with suspicion of CAD were investigated on a dual-layer spectral detector CT (SDCT) scanner. CACS was calculated from both TNC and VNC images by software certified for medical use. Patients with a CACS of 0 were excluded from analysis.!##!Results!#!The mean age of the study population was 61 ± 11 years with 48 male patients (67%). Inter-quartile range of clinical CACS was 22-282. Correlation of measured CACS from true- and VNC images was high (0.95); p < 0.001. The slope was 3.83, indicating an underestimation of VNC CACS compared to TNC CACS by that factor. Visual analysis of the Bland-Altman plot of CACS showed good accordance with both methods after correction of VNC CACS by the abovementioned factor.!##!Conclusions!#!In clinical diagnostics of CAD, the determination of CACS is feasible using VNC images generated from spectral data obtained on a dual-layer spectral detector CT. When multiplied by a correction factor, results were in good agreement with the standard technique. This could enable radiation dose reductions by obviating the need for native scans typically used for CACS.!##!Key points!#!• Calcium scoring is feasible from contrast-enhanced CT images using a dual-layer spectral detector CT scanner. • When multiplied by a correction factor, calcium scoring from virtual non-contrast images shows good agreement with the standard technique. • Omitting native scans for calcium scoring could enable radiation dose reduction.
1000 Sacherschließung
lokal Heart [MeSH]
lokal Vascular calcification
lokal Cardiac
lokal Computed tomography angiography
lokal Aged [MeSH]
lokal Humans [MeSH]
lokal Middle Aged [MeSH]
lokal Tomography, X-Ray Computed [MeSH]
lokal Male [MeSH]
lokal Reproducibility of Results [MeSH]
lokal Coronary Artery Disease/diagnostic imaging [MeSH]
lokal Calcium [MeSH]
lokal Coronary artery disease
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0003-2260-8597|https://frl.publisso.de/adhoc/uri/U2NoYWNreSwgQ2xhdWRpbyBFLg==|https://frl.publisso.de/adhoc/uri/TcO8bGxlci1MZWlzc2UsIENocmlzdGluYQ==|https://frl.publisso.de/adhoc/uri/R2Fzc2VydCwgRmxvcmlhbiBULg==|https://frl.publisso.de/adhoc/uri/UGFobiwgR3JlZ29y|https://frl.publisso.de/adhoc/uri/TGF1Z3dpdHosIEthcmwtTHVkd2ln|https://frl.publisso.de/adhoc/uri/TWFrb3dza2ksIE1hcmN1cyBSLg==|https://frl.publisso.de/adhoc/uri/TmFkamlyaSwgSm9uYXRoYW4=
1000 Hinweis
  • DeepGreen-ID: 2e406d9a2c3645d989cccd61ac44c2e3 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6451269.rdf
1000 Erstellt am 2023-05-11T12:49:25.302+0200
1000 Erstellt von 322
1000 beschreibt frl:6451269
1000 Zuletzt bearbeitet 2023-10-21T04:37:18.125+0200
1000 Objekt bearb. Sat Oct 21 04:37:18 CEST 2023
1000 Vgl. frl:6451269
1000 Oai Id
  1. oai:frl.publisso.de:frl:6451269 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source