Download
s00266-021-02440-y.pdf 1,13MB
WeightNameValue
1000 Titel
  • Standardized Three-Dimensional Lateral Distraction Test: Its Reliability to Assess Medial Canthal Tendon Laxity
1000 Autor/in
  1. Hou, Xiaoyi |
  2. Rokohl, Alexander C. |
  3. Meinke, Marius M. |
  4. Liu, Jinhua |
  5. Li, Senmao |
  6. Fan, Wanlin |
  7. Lin, Ming |
  8. Jia, Renbing |
  9. Guo, Yongwei |
  10. Heindl, Ludwig M. |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-07-07
1000 Erschienen in
1000 Quellenangabe
  • 45(6):2798-2807
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00266-021-02440-y |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8677635/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!Assessment of MCT laxity is critical to the surgery options. Our study aimed to analyze the reliability of measuring medial canthal tendon (MCT) laxity by using a novel standardized three-dimensional lateral distraction test (3D-LDT).!##!Methods!#!Forty-eight Caucasian volunteers (25 males and 23 females, 96 eyes) between 22 and 84 years of age (55.6 ± 18.6 years old) were included in our study. From a neutral position, the lower eyelid was gently pulled laterally along a horizontal line to define the most distracted position of the lower punctum. Both in the neutral and distracted position, standardized 3D images were acquired for each subject by two observers, and each image were measured twice by two raters. Four landmarks and six corresponding linear measurements were evaluated for intra-rater, inter-rater, and inter-method reliability.!##!Results!#!Intra-rater, inter-rater and inter-method reliability analyses of 3D-LDT revealed an intraclass correlation of more than 95%, a mean absolute difference of less than 1 mm, and a technical error of measurement of less than 1 mm. Measurements of relative error (2.59-12.04%) and relative technical error (1.83-16.05%) for the inter-landmarks distance from pupil center to the lower punctum were higher than those from limbus nasal center to the lower punctum (6.13-30.39 and 4.34-26.85%, respectively).!##!Conclusions!#!This study provided high reliability of the three-dimensional lateral distraction test (3D-LDT) for assessing medial canthal tendon (MCT) laxity, which were never evaluated by digital imaging system.!##!Level of evidence iv!#!This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
1000 Sacherschließung
lokal Tendons/surgery [MeSH]
lokal Female [MeSH]
lokal Aged [MeSH]
lokal Adult [MeSH]
lokal Humans [MeSH]
lokal Eyelid
lokal Three dimensional stereophotogrammetry
lokal Middle Aged [MeSH]
lokal Lateral distraction test
lokal Original Article
lokal Eyelids/surgery [MeSH]
lokal Male [MeSH]
lokal Reproducibility of Results [MeSH]
lokal Blepharoplasty [MeSH]
lokal Imaging, Three-Dimensional [MeSH]
lokal Medial canthal tendon laxity
lokal Reliability
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/SG91LCBYaWFveWk=|https://frl.publisso.de/adhoc/uri/Um9rb2hsLCBBbGV4YW5kZXIgQy4=|https://frl.publisso.de/adhoc/uri/TWVpbmtlLCBNYXJpdXMgTS4=|https://frl.publisso.de/adhoc/uri/TGl1LCBKaW5odWE=|https://frl.publisso.de/adhoc/uri/TGksIFNlbm1hbw==|https://frl.publisso.de/adhoc/uri/RmFuLCBXYW5saW4=|https://frl.publisso.de/adhoc/uri/TGluLCBNaW5n|https://frl.publisso.de/adhoc/uri/SmlhLCBSZW5iaW5n|https://orcid.org/0000-0001-9195-0770|https://frl.publisso.de/adhoc/uri/SGVpbmRsLCBMdWR3aWcgTS4=
1000 Hinweis
  • DeepGreen-ID: 6cbd9e00bffd4a5c8508e737baecafc6 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6451365.rdf
1000 Erstellt am 2023-05-11T13:13:47.540+0200
1000 Erstellt von 322
1000 beschreibt frl:6451365
1000 Zuletzt bearbeitet 2023-10-21T04:45:13.072+0200
1000 Objekt bearb. Sat Oct 21 04:45:13 CEST 2023
1000 Vgl. frl:6451365
1000 Oai Id
  1. oai:frl.publisso.de:frl:6451365 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source