Download
s40001-020-00469-4.pdf 1006,56KB
WeightNameValue
1000 Titel
  • Evaluation of intra- and interobserver reliability in the assessment of the ‘critical trochanter angle’
1000 Autor/in
  1. Serong, Sebastian |
  2. Schutzbach, Moritz |
  3. Zovko, Ivica |
  4. Jäger, Marcus |
  5. Landgraeber, Stefan |
  6. Haversath, Marcel |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-12-10
1000 Erschienen in
1000 Quellenangabe
  • 25(1):67
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s40001-020-00469-4 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7731484/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!The recently described 'critical trochanter angle' (CTA) is a novel parameter in the preoperative risk assessment of stem malalignment in total hip arthroplasty. As its reproducibility needs to be evaluated, the given study aims to investigate intra- and interobserver reliability. It is hypothesized that both analyses justify the clinical use of the CTA.!##!Methods!#!A total of 100 pelvic radiographs obtained prior to total hip arthroplasty were retrospectively reviewed by four observers with different levels of clinical experience. The CTA was measured twice by each observer at different occasions in the previously described technique. Intra- and interobserver reliability was evaluated using intraclass correlation coefficients (ICC) with confidence intervals (CI) and the Bland-Altman approach.!##!Results!#!The mean CTA in both measuring sequences was 20.58° and 20.78°. The observers' means ranged from 17.76° to 25.23°. Intraobserver reliability showed a mean difference of less than 0.5° for all four observers (95% limit of agreement: - 7.70-6.70). Intraobserver ICCs ranged from 0.92 to 0.99 (CI 0.88-0.99). For interobserver variation analysis, ICCs of 0.83 (CI 0.67-0.90) and 0.85 (CI 0.68-0.92) were calculated.!##!Conclusion!#!Analyses concerning intra- and interobserver reliability in the assessment of the CTA showed 'very good' and 'good' results, respectively. In view of these findings, the use of the CTA as an additional preoperative parameter to assess the risk of intraoperative stem malalignment seems to be justified.
1000 Sacherschließung
lokal Interobserver
lokal Observer Variation [MeSH]
lokal Radiography [MeSH]
lokal Total hip arthroplasty
lokal Humans [MeSH]
lokal Intraobserver
lokal Retrospective Studies [MeSH]
lokal Femur/diagnostic imaging [MeSH]
lokal Arthroplasty, Replacement, Hip/methods [MeSH]
lokal Research
lokal Stem alignment
lokal Critical trochanter angle
lokal Reliability
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0001-5163-2241|https://frl.publisso.de/adhoc/uri/U2NodXR6YmFjaCwgTW9yaXR6|https://frl.publisso.de/adhoc/uri/Wm92a28sIEl2aWNh|https://frl.publisso.de/adhoc/uri/SsOkZ2VyLCBNYXJjdXM=|https://frl.publisso.de/adhoc/uri/TGFuZGdyYWViZXIsIFN0ZWZhbg==|https://frl.publisso.de/adhoc/uri/SGF2ZXJzYXRoLCBNYXJjZWw=
1000 Hinweis
  • DeepGreen-ID: 2e1b1d54c2cc424fad91ac520d7d656b ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6452364.rdf
1000 Erstellt am 2023-05-12T14:58:48.499+0200
1000 Erstellt von 322
1000 beschreibt frl:6452364
1000 Zuletzt bearbeitet 2023-10-24T07:23:19.446+0200
1000 Objekt bearb. Tue Oct 24 07:23:19 CEST 2023
1000 Vgl. frl:6452364
1000 Oai Id
  1. oai:frl.publisso.de:frl:6452364 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source