Download
am0pahse1918.pdf 465,35KB
WeightNameValue
1000 Titel
  • Polycyclic aromatic hydrocarbons (PAHs) – Method for the determination of semi‐volatile PAHs in workplace air using high performance liquid chromatography (HPLC) : Air Monitoring Method
1000 Titelzusatz
  • Air Monitoring Method – Polycyclic aromatic hydrocarbons (PAHs) – Method for the determination of semi‐volatile PAHs in workplace air using high performance liquid chromatography (HPLC)
1000 Beteiligung
Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe (herausgebende Körperschaft) |
1000 Autor/in
  1. Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe |
  2. Assenmacher‐Maiworm, Heinz |
  3. Hahn, Jens-Uwe |
  4. Heinrich, Birgit |
  5. Schuh, Claudia |
  6. Hebisch, Ralph |
  7. Brock, Thomas Helmut |
  8. Hartwig, Andrea |
  9. MAK Commission |
1000 Erscheinungsjahr 2018
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2018-04-24
1000 Erschienen in
1000 Quellenangabe
  • 3(2):902-917
1000 FRL-Sammlung
1000 Copyrightjahr
  • 2018
1000 Verlagsversion
  • https://doi.org/10.1002/3527600418.am0pahse1918 |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • This analytical method is a validated measurement procedure for the determination of six semi‐volatile polycyclic aromatic hydrocarbons (PAHs) from the EPA list (US Environmental Protection Agency) such as benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenzo[a,h]anthracene, benzo[ghi]perylene, indeno[1,2,3‐cd]pyrene and also benzo[e]pyren in workplace air averaged over the sampling period after personal or stationary sampling. Sampling is performed by drawing a defined volume of air through a PTFE filter, which is inserted in a GSP sampling system. The collected PAH components are extracted with a mixture of acetonitrile/methanol and analysed by means of high performance liquid chromatography (HPLC) with fluorescence detection. The quantitative determination of the PAHs is based on calibration functions obtained by means of multiple‐point calibrations. The limit of quantification for an individual PAH is in the range from 0.0012 to 0.0043 µg/m3. Joint Publication of the Analytical Subcommittee of the Chemistry Board of Experts of the Expert Committee Raw Materials and Chemical Industry of the German Social Accident Insurance and the working group “Air Analyses” of the Permanent Senate Commission of the Deutsche Forschungsgemeinschaft for the Investigation of Health Hazards of Chemical Compounds in the Work Area.
1000 Sacherschließung
lokal workplace measurement
lokal Luftanalysen-Methoden
lokal workplace monitoring
lokal PAH
lokal air sampling
lokal high performance liquid chromatography
lokal polycyclic aromatic hydrocarbons
lokal HPLC
lokal dibenzo[a,h]anthracene
lokal Air Monitoring Methods
lokal fluorescence detection
lokal benzo[k]fluoranthene
lokal benzo[ghi]perylene
lokal benzo[b]fluoranthene
lokal 205-99-2
lokal hazardous substances
lokal measurement method
lokal 50-32-8
lokal 53-70-3
lokal benzo[e]pyrene
lokal PTFE filter
lokal 207-08-9
lokal indeno[1,2,3-cd]pyrene
lokal benzo[a]pyrene
lokal air analysis
1000 Fächerklassifikation (DDC)
1000 DOI 10.4126/FRL01-006453671 |
1000 Liste der Beteiligten
  1. QXNzZW5tYWNoZXLigJBNYWl3b3JtLCBIZWlueg==|SGFobiwgSmVucy1Vd2U=|TGF1dGVyd2FsZCwgSGVpbnJpY2g=|U2NodWgsIENsYXVkaWE=|SGViaXNjaCwgUmFscGg=|QnJvY2ssIFRob21hcyBIZWxtdXQ=|SGFydHdpZywgQW5kcmVh|TUFLIENvbW1pc3Npb24=
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6453671.rdf
1000 Erstellt am 2023-08-22T09:29:30.633+0200
1000 Erstellt von 335
1000 beschreibt frl:6453671
1000 Zuletzt bearbeitet Fri Jan 05 10:45:20 CET 2024
1000 Objekt bearb. Fri Jan 05 10:45:20 CET 2024
1000 Vgl. frl:6453671
1000 Oai Id
  1. oai:frl.publisso.de:frl:6453671 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source