Download
am156902e1919.pdf 456,29KB
WeightNameValue
1000 Titel
  • Glycol esters, glycol ethers – Method for the determination of propylene glycol monoethyl ether, 1‐ethoxy‐2‐propanol acetate, diethylene glycol monomethyl ether, diethylene glycol monoethyl ether and diethylene glycol monobutyl ether in workplace air using gas chromatography : Air Monitoring Method
1000 Titelzusatz
  • Air Monitoring Method – Glycol esters, glycol ethers – Method for the determination of propylene glycol monoethyl ether, 1‐ethoxy‐2‐propanol acetate, diethylene glycol monomethyl ether, diethylene glycol monoethyl ether and diethylene glycol monobutyl ether in workplace air using gas chromatography
1000 Beteiligung
Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe (herausgebende Körperschaft) |
1000 Autor/in
  1. Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe |
  2. Giesen, Yvonne |
  3. Friedrich, Claudia |
  4. Breuer, Dietmar |
  5. Fauss, Jürgen |
  6. Hebisch, Ralph |
  7. Brock, Thomas Helmut |
  8. Hartwig, Andrea |
  9. MAK Commission |
1000 Erscheinungsjahr 2019
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2019-01-30
1000 Erschienen in
1000 Quellenangabe
  • 4(1):285-302
1000 FRL-Sammlung
1000 Copyrightjahr
  • 2019
1000 Verlagsversion
  • https://doi.org/10.1002/3527600418.am156902e1919 |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • This analytical method is a validated measurement procedure for the determination and limit value monitoring of 1‐ethoxy‐2‐propanol, 1‐ethoxy‐2‐propyl acetate, 2‐(2‐methoxyethoxy)ethanol, 2‐(2‐ethoxyethoxy)ethanol and 2‐(2‐butoxyethoxy)ethanol in workplace air. With this method simultaneously airborne glycols in the gaseous state as well as particles are collected. Sampling is performed by drawing a defined volume of air through the sampling system GGP‐Mini consisting of a glass fibre filter and a charcoal tube connected downstream using a suitable flow‐regulated pump. The flow rate is set to 0.33 L/min with a recommended air sample volume of 40 L. The collected glycols are desorbed with a mixture of dichloromethane/methanol containing 1‐hexanol as internal standard and then analysed by means of gas chromatography using FID. The quantitative evaluation is based on calibration functions obtained by means of multiple‐point calibrations. The limit of quantification (LOQ) for the individual glycol esters or glycol ethers is 0.5 mg/m3 based on an air sample volume of 40 L. Joint Publication of the Analytical Subcommittee of the Chemistry Board of Experts of the Expert Committee Raw Materials and Chemical Industry of the German Social Accident Insurance and the working group “Air Analyses” of the Permanent Senate Commission of the Deutsche Forschungsgemeinschaft for the Investigation of Health Hazards of Chemical Compounds in the Work Area.
1000 Sacherschließung
lokal workplace measurement
lokal Luftanalysen-Methoden
lokal GGP-Mini
lokal hazardous substances
lokal workplace monitoring
lokal glycol esters
lokal air sampling
lokal 2-(2-methoxyethoxy)ethanol
lokal gas chromatography
lokal 1-ethoxy-2-propyl acetate
lokal 1-ethoxy-2-propanol
lokal 2-(2-ethoxyethoxy)ethanol
lokal activated charcoal tube
lokal Air Monitoring Methods
lokal air analysis
lokal glass fibre filter
lokal glycol ethers
lokal 2-(2-butoxyethoxy)ethanol
1000 Fächerklassifikation (DDC)
1000 DOI 10.4126/FRL01-006453872 |
1000 Liste der Beteiligten
  1. R2llc2VuLCBZdm9ubmU=|RnJpZWRyaWNoLCBDbGF1ZGlh|QnJldWVyLCBEaWV0bWFy|RmF1c3MsIErDvHJnZW4=|SGViaXNjaCwgUmFscGg=|QnJvY2ssIFRob21hcyBIZWxtdXQ=|SGFydHdpZywgQW5kcmVh|TUFLIENvbW1pc3Npb24=
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6453872.rdf
1000 Erstellt am 2023-08-22T15:51:30.033+0200
1000 Erstellt von 335
1000 beschreibt frl:6453872
1000 Zuletzt bearbeitet 2024-01-04T12:12:10.349+0100
1000 Objekt bearb. Thu Jan 04 12:12:10 CET 2024
1000 Vgl. frl:6453872
1000 Oai Id
  1. oai:frl.publisso.de:frl:6453872 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source