Download
am43103e1917a.pdf 96,44KB
WeightNameValue
1000 Titel
  • Diacetyl (butanedione) – Method for the determination of diacetyl in workplace air using liquid chromatography (HPLC‐UV or HPLC‐MS) : Air Monitoring Method
1000 Titelzusatz
  • Diacetyl Meth. No. 1; Air Monitoring Method – Diacetyl (butanedione) – Method for the determination of diacetyl in workplace air using liquid chromatography (HPLC‐UV or HPLC‐MS)
1000 Beteiligung
Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe (herausgebende Körperschaft) |
1000 Autor/in
  1. Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe |
  2. Schuh, Claudia |
  3. Kirchner, Michael |
  4. Hebisch, Ralph |
  5. Brock, Thomas Helmut |
  6. Hartwig, Andrea |
  7. MAK Commission |
1000 Erscheinungsjahr 2017
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2017-04-28
1000 Erschienen in
1000 Quellenangabe
  • 2(2):1059-1074
1000 FRL-Sammlung
1000 Copyrightjahr
  • 2017
1000 Verlagsversion
  • https://doi.org/10.1002/3527600418.am43103e1917a |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • This analytical method is a validated measurement procedure for the determination of 2,3‐butanedione (diacetyl) in workplace air in a concentration range of a tenth up to twice the currently valid Occupational Exposure Limit (OEL) or MAK value. Sampling is performed by drawing a defined volume of air through a cartridge filled with silica gel impregnated with 2,4‐dinitrophenylhydrazine (DNPH) using a suitable flow‐regulated pump with a volumetric flow rate of 1 mL/min. For sampling 1 hour or 15 min (checking the short‐term value) can be used. The formed diacetyl‐2,4‐DNPH derivatives are desorbed with acetonitrile containing a defined amount of DNPH and analysed by means of liquid chromatography (HPLC‐UV or HPLC‐MS). Quantitative evaluation is based on a 10‐point calibration using methacrolein‐2,4‐DNPH as internal standard. The limit of quantification for diacetyl is 0.002 mg/m3 based on an air sample volume of approx. 60 L or 0.006 mg/m3 based on an air sample volume of approx. 15 L (for short‐term value). Joint Publication of the Analytical Subcommittee of the Chemistry Board of Experts of the Expert Committee Raw Materials and Chemical Industry of the German Social Accident Insurance and the Working Group “Air Monitoring Methods” of the Permanent Senate Commission of the DFG for the Investigation of Health Hazards of Chemical Compounds in the Work Area.
1000 Sacherschließung
lokal workplace measurement
lokal Luftanalysen-Methoden
lokal measuring procedure
lokal hazardous substances
lokal measurement method
lokal workplace monitoring
lokal air sampling
lokal diacetyl
lokal butane-2,3-dione
lokal HPLC
lokal Air Monitoring Methods
lokal air analysis
lokal liquid chromatography
lokal short-term measurement
1000 Fächerklassifikation (DDC)
1000 DOI 10.4126/FRL01-006453904 |
1000 Liste der Beteiligten
  1. U2NodWgsIENsYXVkaWE=|S2lyY2huZXIsIE1pY2hhZWw=|SGViaXNjaCwgUmFscGg=|QnJvY2ssIFRob21hcyBIZWxtdXQ=|SGFydHdpZywgQW5kcmVh|TUFLIENvbW1pc3Npb24=
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6453904.rdf
1000 Erstellt am 2023-08-22T16:00:02.870+0200
1000 Erstellt von 335
1000 beschreibt frl:6453904
1000 Zuletzt bearbeitet Wed Nov 29 16:19:22 CET 2023
1000 Objekt bearb. Wed Nov 29 16:19:22 CET 2023
1000 Vgl. frl:6453904
1000 Oai Id
  1. oai:frl.publisso.de:frl:6453904 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source