Download
am60014e1918b.pdf 354,23KB
WeightNameValue
1000 Titel
  • 2,3‐Pentanedione – Method for the determination of 2,3‐pentanedione in workplace air using gas chromatography‐mass spectrometry (GC‐MS) : Air Monitoring Method
1000 Titelzusatz
  • Air Monitoring Method – 2,3‐Pentanedione – Method for the determination of 2,3‐pentanedione in workplace air using gas chromatography‐mass spectrometry (GC‐MS)
1000 Beteiligung
Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe (herausgebende Körperschaft) |
1000 Autor/in
  1. Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe |
  2. Schuh, Claudia |
  3. Nitschke, Lutz |
  4. Hebisch, Ralph |
  5. Brock, Thomas Helmut |
  6. Hartwig, Andrea |
  7. MAK Commission |
1000 Erscheinungsjahr 2018
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2018-07-26
1000 Erschienen in
1000 Quellenangabe
  • 3(3):1615-1627
1000 FRL-Sammlung
1000 Copyrightjahr
  • 2018
1000 Verlagsversion
  • https://doi.org/10.1002/3527600418.am60014e1918b |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • This analytical method is a validated measurement procedure for the determination of 2,3‐pentanedione in workplace air in a concentration range of a tenth up to twice the currently valid MAK value of 0,083 mg/m3. Sampling is performed by drawing a defined volume of air through a silica gel tube using a suitable flow‐regulated pump. The flow rate is set to 0.33 L/min with a recommended air sample volume of approx. 20 L at a sampling time of 1 hour. For sampling 1 hour or 15 min (checking the short‐term value) can be used. The collected 2,3‐pentanedione is desorbed with acetone containing the internal standard cyclohexanone and then analysed by means of gas chromatography‐mass spectrometry (GC‐MS). The quantitative evaluation is based on a calibration function obtained by means of a 10‐point calibration using cyclohexanone as internal standard. The limit of quantification is 0.0025 mg/m3 based on an air sample volume of approx. 20 L or 0.010 mg/m3 based on an air sample volume of approx. 5 L (for short‐term value). Joint Publication of the Analytical Subcommittee of the Chemistry Board of Experts of the Expert Committee Raw Materials and Chemical Industry of the German Social Accident Insurance and the working group “Air Analyses” of the Permanent Senate Commission of the DFG for the Investigation of Health Hazards of Chemical Compounds in the Work Area.
1000 Sacherschließung
lokal workplace measurement
lokal Luftanalysen-Methoden
lokal gas chromatography-mass spectrometry
lokal 2,3-pentanedione
lokal 600-14-6
lokal measuring procedure
lokal GC-MS
lokal hazardous substances
lokal measurement method
lokal workplace monitoring
lokal air sampling
lokal Air Monitoring Methods
lokal air analysis
lokal short-term measurement
lokal silica gel tube
1000 Fächerklassifikation (DDC)
1000 DOI 10.4126/FRL01-006453971 |
1000 Liste der Beteiligten
  1. U2NodWgsIENsYXVkaWE=|Tml0c2Noa2UsIEx1dHo=|SGViaXNjaCwgUmFscGg=|QnJvY2ssIFRob21hcyBIZWxtdXQ=|SGFydHdpZywgQW5kcmVh|TUFLIENvbW1pc3Npb24=
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6453971.rdf
1000 Erstellt am 2023-08-22T16:17:49.560+0200
1000 Erstellt von 335
1000 beschreibt frl:6453971
1000 Zuletzt bearbeitet 2023-11-29T16:24:57.614+0100
1000 Objekt bearb. Wed Nov 29 16:24:57 CET 2023
1000 Vgl. frl:6453971
1000 Oai Id
  1. oai:frl.publisso.de:frl:6453971 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source