Download
am63008e2019a.pdf 264,64KB
WeightNameValue
1000 Titel
  • Method for the determination of carbon monoxide in workplace air using a non‐dispersive infrared gas measurement device (NDIR) : Air Monitoring Method
1000 Titelzusatz
  • Air Monitoring Method – Method for the determination of carbon monoxide in workplace air using a non‐dispersive infrared gas measurement device (NDIR)
1000 Beteiligung
Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe (herausgebende Körperschaft) |
1000 Autor/in
  1. Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe |
  2. Gluschko, Anastasia |
  3. Brock, Thomas Helmut |
  4. Hebisch, Ralph |
  5. Hartwig, Andrea |
  6. MAK Commission |
1000 Erscheinungsjahr 2019
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2019-04-25
1000 Erschienen in
1000 Quellenangabe
  • 4(2):970-979
1000 FRL-Sammlung
1000 Copyrightjahr
  • 2019
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1002/3527600418.am63008e2019a |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • This analytical method is a validated procedure for the determination of carbon monoxide in workplace air after personal or stationary sampling. Portable, electrically‐powered gas measurement devices with integrated air sampling are used. The sample flow rate is set to 0.5 or 2.0 L/min. The air sample is transferred to the measurement cell by means of an internal sampling pump. Measurement is carried out by comparison of the IR signals of a concentration‐dependent measurement cuvette and the IR signal of the sealed reference cuvette. The current CO concentration is calculated electronically from the respective differences of these cuvettes and then immediately displayed as the measurement result for the CO concentration. This method is suitable for measurement at the workplace over long time periods as well as for short‐term measurements. Also readings of the current CO concentration can be taken any time. The limit of quantification (LOQ) is 1.6 ppm in the measurement range of 0 to 100 ppm. Joint Publication of the Analytical Subcommittee of the Chemistry Board of Experts of the Expert Committee Raw Materials and Chemical Industry of the German Social Accident Insurance and the working group “Air Analyses” of the Permanent Senate Commission of the Deutsche Forschungsgemeinschaft for the Investigation of Health Hazards of Chemical Compounds in the Work Area.
1000 Sacherschließung
lokal workplace measurement
lokal NDIR
lokal analytical method
lokal Luftanalysen-Methoden
lokal hazardous substances
lokal CO
lokal DGUV Information 213-584
lokal carbon oxide
lokal non-dispersive infrared gas measurement device
lokal Air Monitoring Methods
lokal carbon monoxide
lokal air analysis
lokal 630-08-0
1000 Fächerklassifikation (DDC)
1000 DOI 10.4126/FRL01-006453991 |
1000 Liste der Beteiligten
  1. R2x1c2Noa28sIEFuYXN0YXNpYQ==|QnJvY2ssIFRob21hcyBIZWxtdXQ=|SGViaXNjaCwgUmFscGg=|SGFydHdpZywgQW5kcmVh|TUFLIENvbW1pc3Npb24=
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6453991.rdf
1000 Erstellt am 2023-08-22T16:30:26.779+0200
1000 Erstellt von 335
1000 beschreibt frl:6453991
1000 Zuletzt bearbeitet 2023-11-29T16:26:40.977+0100
1000 Objekt bearb. Wed Nov 29 16:26:40 CET 2023
1000 Vgl. frl:6453991
1000 Oai Id
  1. oai:frl.publisso.de:frl:6453991 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source