Download
am7509e2016.pdf 136,70KB
WeightNameValue
1000 Titel
  • Method for the determination of chlorinated hydrocarbons in workplace air using gas chromatography after thermal desorption : Air Monitoring Method
1000 Titelzusatz
  • Chlorinated hydrocarbons Method 03; Air Monitoring Method – Method for the determination of chlorinated hydrocarbons in workplace air using gas chromatography after thermal desorption
1000 Beteiligung
Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe (herausgebende Körperschaft) |
1000 Autor/in
  1. Deutsche Forschungsgemeinschaft. Ständige Senatskommission zur Prüfung Gesundheitsschädlicher Arbeitsstoffe |
  2. Tschickardt, Michael |
  3. Brock, Thomas Helmut |
  4. Hebisch, Ralph |
  5. Hartwig, Andrea |
  6. MAK Commission |
1000 Erscheinungsjahr 2017
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2017-01-26
1000 Erschienen in
1000 Quellenangabe
  • 2(1):233-246
1000 FRL-Sammlung
1000 Copyrightjahr
  • 2017
1000 Verlagsversion
  • https://doi.org/10.1002/3527600418.am7509e2016 |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • This analytical procedure is a validated measurement method for the determination of chlorinated hydrocarbons (CHCs) such as dichloromethane, tetrachloroethylene, 1,1,1‐trichloroethane and trichloroethylene and for monitoring their Occupational Exposure Limits (OELs) or MAK values in workplace air. Sampling is performed by drawing a defined volume of air through an adsorption tube filled with Chromosorb 106 using a flow‐regulated pump. The flow rate is set to 5 mL/min with a recommended air sample volume of 200 mL. The collected chlorinated hydrocarbons are thermally desorbed and analysed by means of gas chromatography fitted with two detectors, a flame ionisation detectors (FID) for quantification and a mass selective detector (MSD) for identification and quantification. The quantitative determination is based on calibration functions obtained by means of 10‐point calibrations. The limits of quantification (LOQs) are determined on the basis of aliquots from 1 to 10 mL of the calibration gases in the lower concentration range. The LOQs ranged from 0.85 to 4.3 mg/m3 based on air sample volumes of 200 mL. The expanded uncertainties ranged from 13 to 23% over the entire measuring range. Joint Publication of the Analytical Subcommittee of the Chemistry Board of Experts of the Expert Committee Raw Materials and Chemical Industry of the German Social Accident Insurance and the Working Group “Air Monitoring Methods” of the Permanent Senate Commission of the DFG for the Investigation of Health Hazards of Chemical Compounds in the Work Area.
1000 Sacherschließung
lokal workplace measurement
lokal analytical method
lokal Luftanalysen-Methoden
lokal measuring procedure
lokal dichloromethane
lokal hazardous substances
lokal measurement method
lokal thermal desorption
lokal trichloroethylene
lokal Chromosorb 106
lokal air sampling
lokal chlorinated hydrocarbons
lokal CHC
lokal adsorption tube
lokal gas chromatography
lokal 1,1,1-trichloroethane
lokal Air Monitoring Methods
lokal air analysis
lokal tetrachloroethylene
lokal 75-09-2
1000 Fächerklassifikation (DDC)
1000 DOI 10.4126/FRL01-006454099 |
1000 Liste der Beteiligten
  1. VHNjaGlja2FyZHQsIE1pY2hhZWw=|QnJvY2ssIFRob21hcyBIZWxtdXQ=|SGViaXNjaCwgUmFscGg=|SGFydHdpZywgQW5kcmVh|TUFLIENvbW1pc3Npb24=
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6454099.rdf
1000 Erstellt am 2023-08-22T16:58:50.427+0200
1000 Erstellt von 335
1000 beschreibt frl:6454099
1000 Zuletzt bearbeitet 2023-11-29T16:35:07.554+0100
1000 Objekt bearb. Wed Nov 29 16:35:07 CET 2023
1000 Vgl. frl:6454099
1000 Oai Id
  1. oai:frl.publisso.de:frl:6454099 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source