Download
s12890-021-01541-3.pdf 1,16MB
WeightNameValue
1000 Titel
  • Periprocedural safety and outcome after pump implantation for intravenous treprostinil administration in patients with pulmonary arterial hypertension
1000 Autor/in
  1. Kamp, Jan C. |
  2. Fuge, Jan |
  3. Karsten, Jan F. |
  4. Rümke, Stefan |
  5. Hoeper, Marius M. |
  6. Park, Da-Hee |
  7. Kühn, Christian |
  8. Olsson, Karen M. |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-05-15
1000 Erschienen in
1000 Quellenangabe
  • 21(1):164
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s12890-021-01541-3 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8126130/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Methods!#!In this retrospective observational study, we analyzed all patients with pulmonary arterial hypertension undergoing LenusPro® pump implantation between November 2013 and October 2019 at our center. Periprocedural safety was assessed by describing all complications that occurred within 28 days after surgery; complications that occurred later were described to assess long-term safety. Clinical outcomes were measured by comparison of clinical parameters and echocardiographic measurements of right ventricular function from baseline to 6-months-follow-up.!##!Results!#!Fifty-four patients underwent LenusPro® pump implantation for intravenous treprostinil treatment during the investigation period. Periprocedural complications occurred in 5 patients; the only anesthesia-related complication (right heart failure with recovery after prolonged intensive care and death in the further course) occurred in the only patient who underwent general anesthesia. All other patients underwent local anesthesia with or without short-acting (analgo-) sedation. Eighteen long-term complications occurred in 15 patients, most notably pump pocket or catheter related problems. Transplant-free survival rates at 1, 2, and 3 years were 77 %, 56 %, and 48 %, respectively.!##!Conclusions!#!Subcutaneous pump implantation under local anesthesia and conscious analgosedation while avoiding intubation and mechanical ventilation is feasible in patients with advanced PAH. Controlled studies are needed to determine the safest anesthetic approach for this procedure.!##!Background/objectives!#!Intravenous treprostinil treatment via a fully implantable pump is a treatment option for patients with advanced pulmonary arterial hypertension. However, there is no consensus on the preferred anesthetic approach for the implantation procedure. Primary objective was to assess periprocedural safety with particular attention to feasibility of local anesthesia and conscious analgosedation instead of general anesthesia. Long-term safety and clinical outcomes were secondary endpoints.
1000 Sacherschließung
lokal Female [MeSH]
lokal Pulmonary arterial hypertension
lokal Adult [MeSH]
lokal Humans [MeSH]
lokal Treatment Outcome [MeSH]
lokal Epoprostenol/adverse effects [MeSH]
lokal Pulmonary Arterial Hypertension/drug therapy [MeSH]
lokal Retrospective Studies [MeSH]
lokal Middle Aged [MeSH]
lokal Treprostinil
lokal Administration, Intravenous [MeSH]
lokal Survival Rate [MeSH]
lokal Epoprostenol/administration
lokal Male [MeSH]
lokal Equipment Failure [MeSH]
lokal Research
lokal Pulmonary Arterial Hypertension/mortality [MeSH]
lokal Pump implantation
lokal Epoprostenol/analogs
lokal Infusion Pumps, Implantable/adverse effects [MeSH]
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/S2FtcCwgSmFuIEMu|https://frl.publisso.de/adhoc/uri/RnVnZSwgSmFu|https://frl.publisso.de/adhoc/uri/S2Fyc3RlbiwgSmFuIEYu|https://frl.publisso.de/adhoc/uri/UsO8bWtlLCBTdGVmYW4=|https://frl.publisso.de/adhoc/uri/SG9lcGVyLCBNYXJpdXMgTS4=|https://frl.publisso.de/adhoc/uri/UGFyaywgRGEtSGVl|https://frl.publisso.de/adhoc/uri/S8O8aG4sIENocmlzdGlhbg==|https://frl.publisso.de/adhoc/uri/T2xzc29uLCBLYXJlbiBNLg==
1000 Hinweis
  • DeepGreen-ID: 79b5b616a51d412ea337538c4ccf9161 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6462661.rdf
1000 Erstellt am 2023-11-15T13:47:31.145+0100
1000 Erstellt von 322
1000 beschreibt frl:6462661
1000 Zuletzt bearbeitet 2023-11-30T20:14:09.098+0100
1000 Objekt bearb. Thu Nov 30 20:14:09 CET 2023
1000 Vgl. frl:6462661
1000 Oai Id
  1. oai:frl.publisso.de:frl:6462661 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source