Download
s12891-021-04200-0.pdf 2,88MB
WeightNameValue
1000 Titel
  • Metacarpal shaft fixation: a biomechanical comparison of dorsal plating, lag screws, and headless compression screws
1000 Autor/in
  1. Dyrna, Felix |
  2. Avery, Daniel M. |
  3. Yoshida, Ryu |
  4. Lam, David |
  5. Oeckenpöhler, Simon |
  6. Cote, Mark P. |
  7. Obopilwe, Elifho |
  8. Rodner, Craig M. |
  9. Mazzocca, Augustus D. |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-04-07
1000 Erschienen in
1000 Quellenangabe
  • 22(1):335
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s12891-021-04200-0 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8025362/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!Metacarpal shaft fractures are common and can be treated nonoperatively. Shortening, angulation, and rotational deformity are indications for surgical treatment. Various forms of treatment with advantages and disadvantages have been documented. The purpose of the study was to determine the stability of fracture fixation with intramedullary headless compression screws in two types of metacarpal shaft fractures and compare them to other common forms of rigid fixation: dorsal plating and lag screw fixation. It was hypothesized that headless compression screws would demonstrate a biomechanical stronger construct.!##!Methods!#!Five matched paired hands (age 60.9 ± 4.6 years), utilizing non-thumb metacarpals, were used for comparative fixation in two fracture types created by an osteotomy. In transverse diaphyseal fractures, fixation by headless compression screws (n = 7) and plating (n = 8) were compared. In long oblique diaphyseal fractures, headless compression screws (n = 8) were compared with plating (n = 8) and lag screws (n = 7). Testing was performed using an MTS frame producing an apex dorsal, three point bending force. Peak load to failure and stiffness were calculated from the load-displacement curve generated.!##!Results!#!For transverse fractures, headless compression screws had a significantly higher stiffness and peak load to failure, means 249.4 N/mm and 584.8 N, than plates, means 129.02 N/mm and 303.9 N (both p < 0.001). For long oblique fractures, stiffness and peak load to failure for headless compression screws were means 209 N/mm and 758.4 N, for plates 258.7 N/mm and 518.5 N, and for lag screws 172.18 N/mm and 234.11 N. There was significance in peak load to failure for headless compression screws vs plates (p = 0.023), headless compression screws vs lag screws (p < 0.001), and plates vs lag screws (p = 0.009). There was no significant difference in stiffness between groups.!##!Conclusion!#!Intramedullary fixation of diaphyseal metacarpal fractures with a headless compression screw provides excellent biomechanical stability. Coupled with lower risks for adverse effects, headless compression screws may be a preferable option for those requiring rapid return to sport or work.!##!Level of evidence!#!Basic Science Study, Biomechanics.
1000 Sacherschließung
lokal Metacarpal fracture
lokal Aged [MeSH]
lokal Headless compression screw
lokal Humans [MeSH]
lokal Biomechanical Phenomena [MeSH]
lokal Middle Aged [MeSH]
lokal Biomechanics
lokal Bone Screws [MeSH]
lokal Fracture Fixation, Internal [MeSH]
lokal Metacarpal Bones/diagnostic imaging [MeSH]
lokal Metacarpal Bones/surgery [MeSH]
lokal Intramedullary screw fixation
lokal Fractures, Bone/surgery [MeSH]
lokal Orthopedics and biomechanics
lokal Research Article
lokal Fractures, Bone/diagnostic imaging [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0003-2078-2241|https://frl.publisso.de/adhoc/uri/QXZlcnksIERhbmllbCBNLg==|https://frl.publisso.de/adhoc/uri/WW9zaGlkYSwgUnl1|https://frl.publisso.de/adhoc/uri/TGFtLCBEYXZpZA==|https://frl.publisso.de/adhoc/uri/T2Vja2VucMO2aGxlciwgU2ltb24=|https://frl.publisso.de/adhoc/uri/Q290ZSwgTWFyayBQLg==|https://frl.publisso.de/adhoc/uri/T2JvcGlsd2UsIEVsaWZobw==|https://frl.publisso.de/adhoc/uri/Um9kbmVyLCBDcmFpZyBNLg==|https://frl.publisso.de/adhoc/uri/TWF6em9jY2EsIEF1Z3VzdHVzIEQu
1000 Hinweis
  • DeepGreen-ID: 46f69803b3c84a6aa1dccc5de968ded6 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6463577.rdf
1000 Erstellt am 2023-11-15T19:27:33.427+0100
1000 Erstellt von 322
1000 beschreibt frl:6463577
1000 Zuletzt bearbeitet Thu Nov 30 21:55:52 CET 2023
1000 Objekt bearb. Thu Nov 30 21:55:52 CET 2023
1000 Vgl. frl:6463577
1000 Oai Id
  1. oai:frl.publisso.de:frl:6463577 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source