  • Implant contamination as a cause of surgical site infection in spinal surgery: are single-use implants a reasonable solution? – a systematic review
1000 Autor/in
  1. Schömig, Friederike |
  2. Perka, Carsten |
  3. Pumberger, Matthias |
  4. Ascherl, Rudolf |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-09-25
1000 Erschienen in
1000 Quellenangabe
  • 21(1):634
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s12891-020-03653-z |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7519515/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!In spine surgery, surgical site infection (SSI) is one of the main perioperative complications and is associated with a higher patient morbidity and longer patient hospitalization. Most factors associated with SSI are connected with asepsis during the surgical procedure and thus with contamination of implants and instruments used which can be caused by pre- and intraoperative factors. In this systematic review we evaluate the current literature on these causes and discuss possible solutions to avoid implant and instrument contamination.!##!Methods!#!A systematic literature search of PubMed addressing implant, instrument and tray contamination in orthopaedic and spinal surgery from 2001 to 2019 was conducted following the PRISMA guidelines. All studies regarding implant and instrument contamination in orthopaedic surgery published in English language were included.!##!Results!#!Thirty-five studies were eligible for inclusion and were divided into pre- and intraoperative causes for implant and instrument contamination. Multiple studies showed that reprocessing of medical devices for surgery may be insufficient and lead to surgical site contamination. Regarding intraoperative causes, contamination of gloves and gowns as well as contamination via air are the most striking factors contributing to microbial contamination.!##!Conclusions!#!Our systematic literature review shows that multiple factors can lead to instrument or implant contamination. Intraoperative causes of contamination can be avoided by implementing behavior such as changing gloves right before handling an implant and reducing the instruments' intraoperative exposure to air. In avoidance of preoperative contamination, there still is a lack of convincing evidence for the use of single-use implants in orthopaedic surgery.
1000 Sacherschließung
lokal Humans [MeSH]
lokal Implant contamination
lokal Orthopedics [MeSH]
lokal Orthopedic Procedures/adverse effects [MeSH]
lokal Neurosurgical Procedures [MeSH]
lokal Surgical Wound Infection/etiology [MeSH]
lokal Surgical Wound Infection/epidemiology [MeSH]
lokal Bacteria
lokal Sterilization
lokal Surgical Wound Infection/diagnosis [MeSH]
lokal Spinal surgery
lokal Single-use implants
lokal Orthopedics and biomechanics
lokal Research Article
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-9224-7363|https://frl.publisso.de/adhoc/uri/UGVya2EsIENhcnN0ZW4=|https://frl.publisso.de/adhoc/uri/UHVtYmVyZ2VyLCBNYXR0aGlhcw==|https://frl.publisso.de/adhoc/uri/QXNjaGVybCwgUnVkb2xm
1000 Hinweis
  • DeepGreen-ID: aca35acacccb4acabbb41906ee973f8a ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6464083.rdf
1000 Erstellt am 2023-11-16T00:10:14.521+0100
1000 Erstellt von 322
1000 beschreibt frl:6464083
1000 Zuletzt bearbeitet Thu Nov 30 23:07:55 CET 2023
1000 Objekt bearb. Thu Nov 30 23:07:55 CET 2023
1000 Vgl. frl:6464083
1000 Oai Id
  1. oai:frl.publisso.de:frl:6464083 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source