Download
s12871-021-01368-9.pdf 1,23MB
WeightNameValue
1000 Titel
  • Correlation of exhaled propofol with Narcotrend index and calculated propofol plasma levels in children undergoing surgery under total intravenous anesthesia - an observational study
1000 Autor/in
  1. Heiderich, Sebastian |
  2. Ghasemi, Tara |
  3. Dennhardt, Nils |
  4. Suempelmann, Robert |
  5. Rigterink, Vanessa |
  6. Nickel, Katja |
  7. Keil, Oliver |
  8. Böthig, Dietmar |
  9. Beck, Christiane |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-05-26
1000 Erschienen in
1000 Quellenangabe
  • 21(1):161
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s12871-021-01368-9 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8149920/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!Exhaled propofol concentrations correlate with propofol concentrations in adult human blood and the brain tissue of rats, as well as with electroencephalography (EEG) based indices of anesthetic depth. The pharmacokinetics of propofol are however different in children compared to adults. The value of exhaled propofol measurements in pediatric anesthesia has not yet been investigated. Breathing system filters and breathing circuits can also interfere with the measurements. In this study, we investigated correlations between exhaled propofol (exP) concentrations and the Narkotrend Index (NI) as well as calculated propofol plasma concentrations.!##!Methods!#!A multi-capillary-column (MCC) combined with ion mobility spectrometry (IMS) was used to determine exP. Optimal positioning of breathing system filters (near-patient or patient-distant) and sample line (proximal or distal to filter) were investigated. Measurements were taken during induction (I), maintenance (M) and emergence (E) of children under total intravenous anesthesia (TIVA). Correlations between ExP concentrations and NI and predicted plasma propofol concentrations (using pediatric pharmacokinetic models Kataria and Paedfusor) were assessed using Pearson correlation and regression analysis.!##!Results!#!Near-patient positioning of breathing system filters led to continuously rising exP values when exP was measured proximal to the filters, and lower concentrations when exP was measured distal to the filters. The breathing system filters were therefore subsequently attached between the breathing system tubes and the inspiratory and expiratory limbs of the anesthetic machine. ExP concentrations significantly correlated with NI and propofol concentrations predicted by pharmacokinetic models during induction and maintenance of anesthesia. During emergence, exP significantly correlated with predicted propofol concentrations, but not with NI.!##!Conclusion!#!In this study, we demonstrated that exP correlates with calculated propofol concentrations and NI during induction and maintenance in pediatric patients. However, the correlations are highly variable and there are substantial obstacles: Without patient proximal placement of filters, the breathing circuit tubing must be changed after each patient, and furthermore, during ventilation, a considerable additional loss of heat and moisture can occur. Adhesion of propofol to plastic parts (endotracheal tube, breathing circle) may especially be problematic during emergence.!##!Trial registration!#!The study was registered in the German registry of clinical studies (DRKS-ID:  DRKS00015795 ).
1000 Sacherschließung
lokal Female [MeSH]
lokal Exhalation [MeSH]
lokal TIVA
lokal Humans [MeSH]
lokal Prospective Studies [MeSH]
lokal Pediatric anesthesia
lokal Anesthetics, Intravenous/pharmacokinetics [MeSH]
lokal Propofol/blood [MeSH]
lokal Propofol/pharmacokinetics [MeSH]
lokal Pharmacokinetic modeling
lokal Infant [MeSH]
lokal Male [MeSH]
lokal Reproducibility of Results [MeSH]
lokal Children
lokal Anesthetics, Intravenous/blood [MeSH]
lokal Exhaled propofol
lokal Research
lokal Anesthesia, Intravenous/methods [MeSH]
lokal Child [MeSH]
lokal Monitoring, Intraoperative/methods [MeSH]
lokal Child, Preschool [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-5742-5558|https://frl.publisso.de/adhoc/uri/R2hhc2VtaSwgVGFyYQ==|https://orcid.org/0000-0003-3831-1608|https://orcid.org/0000-0001-5850-7443|https://frl.publisso.de/adhoc/uri/UmlndGVyaW5rLCBWYW5lc3Nh|https://frl.publisso.de/adhoc/uri/Tmlja2VsLCBLYXRqYQ==|https://frl.publisso.de/adhoc/uri/S2VpbCwgT2xpdmVy|https://frl.publisso.de/adhoc/uri/QsO2dGhpZywgRGlldG1hcg==|https://orcid.org/0000-0002-7179-0084
1000 Hinweis
  • DeepGreen-ID: 8a8c49d76cf04217bc2e884964cba8ac ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6465187.rdf
1000 Erstellt am 2023-11-16T10:47:41.305+0100
1000 Erstellt von 322
1000 beschreibt frl:6465187
1000 Zuletzt bearbeitet Fri Dec 01 01:46:28 CET 2023
1000 Objekt bearb. Fri Dec 01 01:46:28 CET 2023
1000 Vgl. frl:6465187
1000 Oai Id
  1. oai:frl.publisso.de:frl:6465187 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source