Download
s12873-021-00409-3.pdf 828,34KB
WeightNameValue
1000 Titel
  • Testing mechanical chest compression devices of different design for their suitability for prehospital patient transport - a simulator-based study
1000 Autor/in
  1. Jörgens, Maximilian |
  2. Königer, Jürgen |
  3. Kanz, Karl-Georg |
  4. Birkholz, Torsten |
  5. Hübner, Heiko |
  6. Prückner, Stephan |
  7. Zwissler, Bernhard |
  8. Trentzsch, Heiko |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-02-04
1000 Erschienen in
1000 Quellenangabe
  • 21(1):18
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s12873-021-00409-3 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7860178/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!Mechanical chest compression (mCPR) offers advantages during transport under cardiopulmonary resuscitation. Little is known how devices of different design perform en-route. Aim of the study was to measure performance of mCPR devices of different construction-design during ground-based pre-hospital transport.!##!Methods!#!We tested animax mono (AM), autopulse (AP), corpuls cpr (CC) and LUCAS2 (L2). The route had 6 stages (transport on soft stretcher or gurney involving a stairwell, trips with turntable ladder, rescue basket and ambulance including loading/unloading). Stationary mCPR with the respective device served as control. A four-person team carried an intubated and bag-ventilated mannequin under mCPR to assess device-stability (displacement, pressure point correctness), compliance with 2015 ERC guideline criteria for high-quality chest compressions (frequency, proportion of recommended pressure depth and compression-ventilation ratio) and user satisfaction (by standardized questionnaire).!##!Results!#!All devices performed comparable to stationary use. Displacement rates ranged from 83% (AM) to 11% (L2). Two incorrect pressure points occurred over 15,962 compressions (0.013%). Guideline-compliant pressure depth was > 90% in all devices. Electrically powered devices showed constant frequencies while muscle-powered AM showed more variability (median 100/min, interquartile range 9). Although physical effort of AM use was comparable (median 4.0 vs. 4.5 on visual scale up to 10), participants preferred electrical devices.!##!Conclusion!#!All devices showed good to very good performance although device-stability, guideline compliance and user satisfaction varied by design. Our results underline the importance to check stability and connection to patient under transport.
1000 Sacherschließung
lokal Mechanical chest compressions
lokal Pre-hospital emergency medical services
lokal Manikins [MeSH]
lokal Cardio-pulmonary resuscitation
lokal Humans [MeSH]
lokal Ambulances [MeSH]
lokal Device stability
lokal Cardiopulmonary Resuscitation [MeSH]
lokal Emergency Medical Services [MeSH]
lokal Research Article
lokal Transport
lokal Trauma emergency medicine
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/SsO2cmdlbnMsIE1heGltaWxpYW4=|https://frl.publisso.de/adhoc/uri/S8O2bmlnZXIsIErDvHJnZW4=|https://frl.publisso.de/adhoc/uri/S2FueiwgS2FybC1HZW9yZw==|https://frl.publisso.de/adhoc/uri/Qmlya2hvbHosIFRvcnN0ZW4=|https://frl.publisso.de/adhoc/uri/SMO8Ym5lciwgSGVpa28=|https://frl.publisso.de/adhoc/uri/UHLDvGNrbmVyLCBTdGVwaGFu|https://frl.publisso.de/adhoc/uri/Wndpc3NsZXIsIEJlcm5oYXJk|https://orcid.org/0000-0002-6395-6873
1000 Hinweis
  • DeepGreen-ID: f5e4ea0e2415470f8f185835e8325b43 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6465215.rdf
1000 Erstellt am 2023-11-16T11:12:24.734+0100
1000 Erstellt von 322
1000 beschreibt frl:6465215
1000 Zuletzt bearbeitet Fri Dec 01 01:49:26 CET 2023
1000 Objekt bearb. Fri Dec 01 01:49:26 CET 2023
1000 Vgl. frl:6465215
1000 Oai Id
  1. oai:frl.publisso.de:frl:6465215 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source