Download
s12871-020-01110-x.pdf 1,30MB
WeightNameValue
1000 Titel
  • Perioperative non-invasive versus semi-invasive cardiac index monitoring in patients with bariatric surgery – a prospective observational study
1000 Autor/in
  1. Lorenzen, Ulf |
  2. Pohlmann, Markus |
  3. Hansen, Jonathan |
  4. Klose, Phil |
  5. Gruenewald, Matthias |
  6. Renner, Jochen |
  7. Elke, Gunnar |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-08-10
1000 Erschienen in
1000 Quellenangabe
  • 20(1):196
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s12871-020-01110-x |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7419223/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!In morbidly obese patients undergoing laparoscopic bariatric surgery, the combination of obesity-related comorbidities, pneumoperitoneum and extreme posture changes constitutes a high risk of perioperative hemodynamic complications. Thus, an advanced hemodynamic monitoring including continuous cardiac index (CI) assessment is desirable. While invasive catheterization may bear technical difficulties, transesophageal echocardiography is contraindicated due to the surgical procedure. Evidence on the clinical reliability of alternative semi- or non-invasive cardiac monitoring devices is limited. The aim was to compare the non-invasive vascular unloading to a semi-invasive pulse contour analysis reference technique for continuous CI measurements in bariatric surgical patients.!##!Methods!#!This prospective observational study included adult patients scheduled for elective, laparoscopic bariatric surgery after obtained institutional ethics approval and written informed consent. CI measurements were performed using the vascular unloading technique (Nexfin®) and semi-invasive reference method (FloTrac™). At 10 defined measurement time points, the influence of clinically indicated body posture changes, passive leg raising, fluid bolus administration and pneumoperitoneum was evaluated pre- and intraoperatively. Correlation, Bland-Altman and concordance analyses were performed.!##!Results!#!Sixty patients (mean BMI 49.2 kg/m!##!Conclusion!#!Non-invasive as compared to semi-invasive CI measurements did not reach criteria of interchangeability for monitoring absolute and trending values of CI in morbidly obese patients undergoing bariatric surgery.!##!Trial registration!#!The study was registered retrospectively on June 12, 2017 with the registration number NCT03184272 .
1000 Sacherschließung
lokal Perioperative medicine and outcome
lokal Bariatric Surgery/methods [MeSH]
lokal Cohort Studies [MeSH]
lokal Male [MeSH]
lokal Bariatric surgery
lokal Hemodynamic monitoring
lokal Obesity, Morbid/physiopathology [MeSH]
lokal Blood Pressure/physiology [MeSH]
lokal Heart Rate/physiology [MeSH]
lokal Obesity, Morbid/diagnosis [MeSH]
lokal Research Article
lokal Monitoring, Intraoperative/methods [MeSH]
lokal Obesity
lokal Female [MeSH]
lokal Adult [MeSH]
lokal Humans [MeSH]
lokal Obesity, Morbid/surgery [MeSH]
lokal Prospective Studies [MeSH]
lokal Bariatric Surgery/adverse effects [MeSH]
lokal Cardiac Output/physiology [MeSH]
lokal Retrospective Studies [MeSH]
lokal Middle Aged [MeSH]
lokal Finger-cuff
lokal Cardiac output
lokal Patient Positioning/methods [MeSH]
lokal Vascular unloading technique
lokal Non-invasive monitoring
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/TG9yZW56ZW4sIFVsZg==|https://frl.publisso.de/adhoc/uri/UG9obG1hbm4sIE1hcmt1cw==|https://frl.publisso.de/adhoc/uri/SGFuc2VuLCBKb25hdGhhbg==|https://frl.publisso.de/adhoc/uri/S2xvc2UsIFBoaWw=|https://frl.publisso.de/adhoc/uri/R3J1ZW5ld2FsZCwgTWF0dGhpYXM=|https://frl.publisso.de/adhoc/uri/UmVubmVyLCBKb2NoZW4=|https://orcid.org/0000-0002-4948-1605
1000 Hinweis
  • DeepGreen-ID: 3660704f61d843fcb699596a2eb97bd5 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6466124.rdf
1000 Erstellt am 2023-11-16T18:48:03.367+0100
1000 Erstellt von 322
1000 beschreibt frl:6466124
1000 Zuletzt bearbeitet 2023-12-01T03:42:39.176+0100
1000 Objekt bearb. Fri Dec 01 03:42:39 CET 2023
1000 Vgl. frl:6466124
1000 Oai Id
  1. oai:frl.publisso.de:frl:6466124 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source