Download
s00405-020-06226-x.pdf 929,67KB
WeightNameValue
1000 Titel
  • Automated detection of electrically evoked stapedius reflexes (eSR) during cochlear implantation
1000 Autor/in
  1. Weiss, Nora |
  2. Óvári, Attila |
  3. Oberhoffner, Tobias |
  4. Demaret, Laurent |
  5. Bicer, Atabek |
  6. Schraven, Sebastian |
  7. Ehrt, Karsten |
  8. Dahl, Rüdiger |
  9. Schneider, Armin |
  10. Mlynski, Robert |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-08-03
1000 Erschienen in
1000 Quellenangabe
  • 278(6):1773-1779
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00405-020-06226-x |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8131305/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Introduction!#!In cochlear implantation, objective fitting methods are needed to optimize audiological results in small children or patients with poor compliance. Intraoperatively measured electrically evoked stapedius reflexes (eSR) can be used as a marker for the patient's discomfort level. The aim of this study was to develop and evaluate an automated detection method for eSR and to compare it to the detection rate of the surgeon and independent observers.!##!Methods!#!Cochlear implantation using a fully digital surgical microscope was performed. Movements of the stapedius tendon were recorded and analyzed by means of computer vision technique. Differences in eSR elicited by stimulating electrodes at different cochlear locations (basal, middle and apical) were analyzed. The eSR detection rate of the image processing algorithm was compared to the surgeon's detection rate and to those of two less experienced observers.!##!Results!#!A total of 387 electrically impulses were applied. The stimulation of middle turn electrodes showed significantly higher detection rates (50.4%) compared to the basal (40.0%; p = 0.001) and apical (43.6%; p = 0.03) turn. The software identified significantly more of the applied stimuli (58.4%) compared to the surgeon (46.3%; p = 0.0007), the intermediate observer (37.7%; p < 0.0001) and the unexperienced observer (41.3%; p < 0.0001).!##!Conclusion!#!The feasibility of an automated intraoperative software-based detection of eSR is demonstrated. By improving the eSR detection methods and their clinical applicability, their utility in objective cochlear implant fitting may be substantially increased.
1000 Sacherschließung
lokal Stapedius [MeSH]
lokal Humans [MeSH]
lokal Objective cochlear implant fitting
lokal Reflex, Acoustic [MeSH]
lokal Cochlear Implantation [MeSH]
lokal Auditory Threshold [MeSH]
lokal Electric Stimulation [MeSH]
lokal Otology
lokal Cochlea implantation
lokal eSRT
lokal Cochlear Implants [MeSH]
lokal Electrically evoked stapedius reflex thresholds
lokal Child [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-0645-3591|https://frl.publisso.de/adhoc/uri/w5N2w6FyaSwgQXR0aWxh|https://frl.publisso.de/adhoc/uri/T2JlcmhvZmZuZXIsIFRvYmlhcw==|https://frl.publisso.de/adhoc/uri/RGVtYXJldCwgTGF1cmVudA==|https://frl.publisso.de/adhoc/uri/QmljZXIsIEF0YWJlaw==|https://frl.publisso.de/adhoc/uri/U2NocmF2ZW4sIFNlYmFzdGlhbg==|https://frl.publisso.de/adhoc/uri/RWhydCwgS2Fyc3Rlbg==|https://frl.publisso.de/adhoc/uri/RGFobCwgUsO8ZGlnZXI=|https://frl.publisso.de/adhoc/uri/U2NobmVpZGVyLCBBcm1pbg==|https://frl.publisso.de/adhoc/uri/TWx5bnNraSwgUm9iZXJ0
1000 Hinweis
  • DeepGreen-ID: 52693609a4424f7a90e1ea8d7a2544da ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6466250.rdf
1000 Erstellt am 2023-11-16T21:18:45.862+0100
1000 Erstellt von 322
1000 beschreibt frl:6466250
1000 Zuletzt bearbeitet 2023-12-01T03:55:12.612+0100
1000 Objekt bearb. Fri Dec 01 03:55:12 CET 2023
1000 Vgl. frl:6466250
1000 Oai Id
  1. oai:frl.publisso.de:frl:6466250 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source