Download
s10792-020-01532-z.pdf 304,25KB
WeightNameValue
1000 Titel
  • Comparable effects on tear film parameters after femtosecond laser-assisted and conventional cataract surgery
1000 Autor/in
  1. Schargus, Marc |
  2. Ivanova, Svetlana |
  3. Stute, Gesa |
  4. Dick, H. Burkhard |
  5. Joachim, Stephanie C. |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-08-03
1000 Erschienen in
1000 Quellenangabe
  • 40(11):3097-3104
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s10792-020-01532-z |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7550384/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Purpose!#!Dry eye symptoms after conventional cataract surgery are a very common problem. Until now, only few data are available on objective tear film parameters in regard to femtosecond laser-assisted cataract surgery (LCS). Aim of this study was therefore to analyze and compare tear film parameter changes between LCS and conventional cataract surgery.!##!Methods!#!A consecutive group of 34 patients, scheduled for cataract surgery, were randomly selected for either LCS or conventional cataract surgery (17 patients/group). Tear film assessments including tear film osmolarity, Schirmer test, MMP-9 analysis via quantitative ELISA, corneal sensitivity, corneal fluorescein staining, and conjunctival fluorescein staining were sequentially evaluated pre- as well as 1 and 3 months postoperatively.!##!Results!#!Both groups showed no significant difference in baseline characteristics. All surgeries were performed without any complications. After 1 and 3 months, there was no statistically significant difference in regard to tear film osmolarity (1 month: p = 0.81, 3 months: p = 1.0), Schirmer test (1 month: p = 0.35, 3 month: p = 0.08), and MMP-9 concentration (1 month: p = 0.36, 3 month: p = 0.28) between the two groups.!##!Conclusions!#!Neither LCS nor conventional cataract surgery affected objective tear film parameters significantly during our 3-month postoperative observation period. Hence, both surgical techniques can be equally used to treat patients without prior dry eye symptoms.
1000 Sacherschließung
lokal MMP-9
lokal Humans [MeSH]
lokal Conventional cataract surgery
lokal Cataract Extraction [MeSH]
lokal Dry Eye Syndromes/diagnosis [MeSH]
lokal Tear film parameters
lokal Lasers [MeSH]
lokal Femtosecond laser-assisted cataract surgery
lokal Dry eye
lokal Original Paper
lokal Cataract [MeSH]
lokal Tears [MeSH]
lokal Dry Eye Syndromes/etiology [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0003-4445-4103|https://frl.publisso.de/adhoc/uri/SXZhbm92YSwgU3ZldGxhbmE=|https://frl.publisso.de/adhoc/uri/U3R1dGUsIEdlc2E=|https://frl.publisso.de/adhoc/uri/RGljaywgSC4gQnVya2hhcmQ=|https://frl.publisso.de/adhoc/uri/Sm9hY2hpbSwgU3RlcGhhbmllIEMu
1000 Hinweis
  • DeepGreen-ID: fc72c88936584a4f9eb45cee1360dd76 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6466498.rdf
1000 Erstellt am 2023-11-16T23:49:51.491+0100
1000 Erstellt von 322
1000 beschreibt frl:6466498
1000 Zuletzt bearbeitet Fri Dec 01 04:22:55 CET 2023
1000 Objekt bearb. Fri Dec 01 04:22:55 CET 2023
1000 Vgl. frl:6466498
1000 Oai Id
  1. oai:frl.publisso.de:frl:6466498 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source