Download
s00402-020-03619-9.pdf 2,18MB
WeightNameValue
1000 Titel
  • Overlengthening of the radial column in radial head replacement: a review of the literature and presentation of a classification system
1000 Autor/in
  1. Wegmann, Kilian |
  2. Hackl, M. |
  3. Leschinger, T. |
  4. Burkhart, K. J. |
  5. Müller, L. P. |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-10-14
1000 Erschienen in
1000 Quellenangabe
  • 141(9):1525-1539
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00402-020-03619-9 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8354917/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!Radial head arthroplasty is a common procedure in elbow surgery. It has been shown to be of benefit for the patients, but there also are relevant complications that should be prevented if possible. One significant complication is overlengthening of the radial head prosthesis. In overlengthening, the head of the prosthesis overextends the physiological level of the native radial head and leads to overcompression in the radiohumeral joint. Rapid erosion and arthritic changes may then impede the clinical outcome. The incidence of overlengthening is not precisely known, but estimations range to up to 20% of all implanted prostheses.!##!Methods!#!The present review discusses the available body of literature on overlengthening and lines out a classification system that may be used to guide treatment algorithms. The classification is based on the personal experiences of the author during their clinical practice.!##!Results!#!In low-grade overlengthening (type I) conservative treatment can be an option. In Types II-IV usually revision surgery is needed. Depending on the state of the capitulum and joint stability, it is possible re-implant a prosthesis, or rely on implant removal alone.!##!Discussion!#!The present review aimed at shedding light into overlengthening as a complication radial head replacement and to help identify and treat it.
1000 Sacherschließung
lokal Erosion
lokal Radial head
lokal Radius/surgery [MeSH]
lokal Elbow Joint/surgery [MeSH]
lokal Trauma Surgery
lokal Elbow
lokal Prosthesis Implantation [MeSH]
lokal Humans [MeSH]
lokal Arthroplasty
lokal Overlengthening
lokal Radius Fractures/surgery [MeSH]
lokal Elbow Prosthesis [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0001-5961-1912|https://frl.publisso.de/adhoc/uri/SGFja2wsIE0u|https://frl.publisso.de/adhoc/uri/TGVzY2hpbmdlciwgVC4=|https://frl.publisso.de/adhoc/uri/QnVya2hhcnQsIEsuIEou|https://frl.publisso.de/adhoc/uri/TcO8bGxlciwgTC4gUC4=
1000 Hinweis
  • DeepGreen-ID: bf143fd4162e4a62998f25f06287c1e9 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6466606.rdf
1000 Erstellt am 2023-11-17T00:41:39.517+0100
1000 Erstellt von 322
1000 beschreibt frl:6466606
1000 Zuletzt bearbeitet 2023-12-01T04:33:29.260+0100
1000 Objekt bearb. Fri Dec 01 04:33:29 CET 2023
1000 Vgl. frl:6466606
1000 Oai Id
  1. oai:frl.publisso.de:frl:6466606 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source