  • Radiation exposure during retrograde intrarenal surgery (RIRS): a prospective multicenter evaluation
1000 Autor/in
  1. Hein, Simon |
  2. Wilhelm, Konrad |
  3. Miernik, Arkadiusz |
  4. Schoenthaler, Martin |
  5. Suarez-Ibarrola, Rodrigo |
  6. Gratzke, Christian |
  7. Salem, Johannes |
  8. Karapanos, Leonidas |
  9. Netsch, Christopher |
  10. Becker, Benedikt |
  11. Secker, Armin |
  12. Veser, Julian |
  13. Neisius, Andreas |
  14. Fritsche, Hans-Martin |
  15. Schnabel, Marco Julius |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-03-21
1000 Erschienen in
1000 Quellenangabe
  • 39(1):217-224
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00345-020-03160-9 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7858553/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Purpose!#!Retrograde intrarenal surgery (RIRS) may require extensive X-ray usage. We evaluated the impact of preoperative surgeon briefing regarding the inclusion and evaluation of fluoroscopy time (FT) and dose area product (DAP) in a multicenter study on the applied X-ray usage.!##!Methods!#!A prospective multicenter study of 6 tertiary centers was performed. Each center recruited up to 25 prospective patients with renal stones of any size for RIRS. Prior to study´s onset, all surgeons were briefed about hazards of radiation and on strategies to avoid high doses in RIRS. Prospective procedures were compared to past procedures, as baseline data. FT was defined as the primary outcome. Secondary parameters were stone-free rate (SFR), complications according to the Clavien, SATAVA and postureteroscopic lesion scale. Results were analyzed using T test, chi-squared test, univariate analysis and confirmed in a multivariate regression model.!##!Results!#!303 patients were included (145 retro- and 158 prospective). Mean FT and DAP were reduced from 130.8 s/565.8 to 77.4 s/357.8 (p < 0.05). SFR was improved from 85.5% to 93% (p < 0.05). Complications did not vary significantly. Neither stone position (p = 0.569), prestenting (p = 0.419), nor surgeons' experience (> 100 RIRS) had a significant impact on FT. Significant univariate parameters were confirmed in a multivariate model, revealing X-ray training to be radiation protective (OR - 44, p = 0.001).!##!Conclusions!#!Increased surgeon awareness of X-ray exposure risks has a significant impact on FT and DAP. This 'awareness effect' is a simple method to reduce radiation exposure for the patient and OR staff without the procedures´ outcome and safety being affected.
1000 Sacherschließung
lokal Female [MeSH]
lokal Urologic Surgical Procedures/methods [MeSH]
lokal Humans [MeSH]
lokal Prospective Studies [MeSH]
lokal Flexible ureteroscopy
lokal Middle Aged [MeSH]
lokal Kidney/surgery [MeSH]
lokal Urolithiasis
lokal Kidney Calculi/surgery [MeSH]
lokal Original Article
lokal Fluoroscopy
lokal Ionizing radiation exposure
lokal Male [MeSH]
lokal X-ray exposure
lokal Radiation Exposure/statistics
lokal Nephrolithiasis
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-9191-3264|https://frl.publisso.de/adhoc/uri/V2lsaGVsbSwgS29ucmFk|https://frl.publisso.de/adhoc/uri/TWllcm5paywgQXJrYWRpdXN6|https://frl.publisso.de/adhoc/uri/U2Nob2VudGhhbGVyLCBNYXJ0aW4=|https://frl.publisso.de/adhoc/uri/U3VhcmV6LUliYXJyb2xhLCBSb2RyaWdv|https://frl.publisso.de/adhoc/uri/R3JhdHprZSwgQ2hyaXN0aWFu|https://frl.publisso.de/adhoc/uri/U2FsZW0sIEpvaGFubmVz|https://frl.publisso.de/adhoc/uri/S2FyYXBhbm9zLCBMZW9uaWRhcw==|https://frl.publisso.de/adhoc/uri/TmV0c2NoLCBDaHJpc3RvcGhlcg==|https://frl.publisso.de/adhoc/uri/QmVja2VyLCBCZW5lZGlrdA==|https://frl.publisso.de/adhoc/uri/U2Vja2VyLCBBcm1pbg==|https://frl.publisso.de/adhoc/uri/VmVzZXIsIEp1bGlhbg==|https://frl.publisso.de/adhoc/uri/TmVpc2l1cywgQW5kcmVhcw==|https://frl.publisso.de/adhoc/uri/RnJpdHNjaGUsIEhhbnMtTWFydGlu|https://frl.publisso.de/adhoc/uri/U2NobmFiZWwsIE1hcmNvIEp1bGl1cw==
1000 Hinweis
  • DeepGreen-ID: 8631e5e8d4564ce98ad173786042faa6 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6466834.rdf
1000 Erstellt am 2023-11-17T03:38:51.265+0100
1000 Erstellt von 322
1000 beschreibt frl:6466834
1000 Zuletzt bearbeitet Fri Dec 01 04:56:26 CET 2023
1000 Objekt bearb. Fri Dec 01 04:56:26 CET 2023
1000 Vgl. frl:6466834
1000 Oai Id
  1. oai:frl.publisso.de:frl:6466834 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source