  • In vitro performance evaluation of AnaConDaTM-100 and AnaConDaTM-50 compared to a circle breathing system for control and consumption of volatile anaesthetics
1000 Autor/in
  1. Bellgardt, Martin |
  2. Drees, Dominik |
  3. Vinnikov, Vladimir |
  4. Georgevici, Adrian I. |
  5. Procopiuc, Livia |
  6. Weber, Thomas P. |
  7. Meiser, Andreas |
  8. Herzog-Niescery, Jennifer |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-12-21
1000 Erschienen in
1000 Quellenangabe
  • 36(1):169-177
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s10877-020-00634-4 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7751266/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • To identify the better volatile anaesthetic delivery system in an intensive care setting, we compared the circle breathing system and two models of reflection systems (AnaConDa™ with a dead space of 100 ml (ACD-100) or 50 ml (ACD-50)). These systems were analysed for the parameters like wash-in, consumption, and wash-out of isoflurane and sevoflurane utilising a test lung model. The test lung was connected to a respirator (circle breathing system: Aisys CS™; ACD-100/50: Puriton Bennett 840). Set parameters were volume-controlled mode, tidal volume-500 ml, respiratory rate-10/min, inspiration time-2 sec, PEEP-5 mbar, and oxygen-21%. Wash-in, consumption, and wash-out were investigated at fresh gas flows of 0.5, 1.0, 2.5, and 5.0 l/min. Anaesthetic target concentrations were 0.5, 1.0, 1.5, 2.0, and 2.5%.  Wash-in was slower in ACD-100/-50 compared to the circle breathing system, except for fresh gas flows of 0.5 and 1.0 l/min. The consumption of isoflurane and sevoflurane in ACD-100 and ACD-50 corresponded to the fresh gas flow of 0.5-1.0 l/min in the circle breathing system. Consumption with ACD-50 was higher in comparison to ACD-100, especially at gas concentrations > 1.5%. Wash-out was quicker in ACD-100/-50 than in the circle breathing system at a fresh gas flow of 0.5 l/min, however, it was longer at all the other flow rates. Wash-out was comparable in ACD-100 and ACD-50. Wash-in and wash-out were generally quicker with the circle breathing system than in ACD-100/-50. However, consumption at 0.5 minimum alveolar concentration was comparable at flows of 0.5 and 1.0 l/min.
1000 Sacherschließung
lokal Humans [MeSH]
lokal Sevoflurane [MeSH]
lokal Anesthetics, Inhalation [MeSH]
lokal Animals [MeSH]
lokal AnaConDaTM
lokal Costs
lokal Circle breathing system
lokal Anesthesia, Inhalation [MeSH]
lokal Isoflurane
lokal Boidae [MeSH]
lokal Isoflurane [MeSH]
lokal Sevoflurane
lokal Original Research
lokal Inhalation Anaesthetics
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0001-9447-0019|https://frl.publisso.de/adhoc/uri/RHJlZXMsIERvbWluaWs=|https://frl.publisso.de/adhoc/uri/Vmlubmlrb3YsIFZsYWRpbWly|https://frl.publisso.de/adhoc/uri/R2VvcmdldmljaSwgQWRyaWFuIEku|https://frl.publisso.de/adhoc/uri/UHJvY29waXVjLCBMaXZpYQ==|https://frl.publisso.de/adhoc/uri/V2ViZXIsIFRob21hcyBQLg==|https://frl.publisso.de/adhoc/uri/TWVpc2VyLCBBbmRyZWFz|https://frl.publisso.de/adhoc/uri/SGVyem9nLU5pZXNjZXJ5LCBKZW5uaWZlcg==
1000 Hinweis
  • DeepGreen-ID: 9025a7e3f18246b188ca584e2f29b778 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6468460.rdf
1000 Erstellt am 2023-11-17T16:31:09.767+0100
1000 Erstellt von 322
1000 beschreibt frl:6468460
1000 Zuletzt bearbeitet Fri Dec 01 07:56:10 CET 2023
1000 Objekt bearb. Fri Dec 01 07:56:10 CET 2023
1000 Vgl. frl:6468460
1000 Oai Id
  1. oai:frl.publisso.de:frl:6468460 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source