1000 Titel
  • Automatic intraoperative optical coherence tomography positioning
1000 Autor/in
  1. Grimm, Matthias |
  2. Roodaki, Hessam |
  3. Eslami, Abouzar |
  4. Navab, Nassir |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-04-02
1000 Erschienen in
1000 Quellenangabe
  • 15(5):781-789
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s11548-020-02135-w |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7261282/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Purpose!#!Intraoperative optical coherence tomography (iOCT) was recently introduced as a new modality for ophthalmic surgeries. It provides real-time cross-sectional information at a very high resolution. However, properly positioning the scan location during surgery is cumbersome and time-consuming, as a surgeon needs both his hands for surgery. The goal of the present study is to present a method to automatically position an iOCT scan on an anatomy of interest in the context of anterior segment surgeries.!##!Methods!#!First, a voice recognition algorithm using a context-free grammar is used to obtain the desired pose from the surgeon. Then, the limbus circle is detected in the microscope image and the iOCT scan is placed accordingly in the X-Y plane. Next, an iOCT sweep in Z direction is conducted and the scan is placed to centre the topmost structure. Finally, the position is fine-tuned using semantic segmentation and a rule-based system.!##!Results!#!The logic to position the scan location on various anatomies was evaluated on ex vivo porcine eyes (10 eyes for corneal apex and 7 eyes for cornea, sclera and iris). The mean euclidean distances (± standard deviation) was 76.7 (± 59.2) pixels and 0.298 (± 0.229) mm. The mean execution time (± standard deviation) in seconds for the four anatomies was 15 (± 1.2). The scans have a size of 1024 by 1024 pixels. The method was implemented on a Carl Zeiss OPMI LUMERA 700 with RESCAN 700.!##!Conclusion!#!The present study introduces a method to fully automatically position an iOCT scanner. Providing the possibility of changing the OCT scan location via voice commands removes the burden of manual device manipulation from surgeons. This in turn allows them to keep their focus on the surgical task at hand and therefore increase the acceptance of iOCT in the operating room.
1000 Sacherschließung
lokal Algorithms [MeSH]
lokal Swine [MeSH]
lokal Automatic positioning
lokal Cross-Sectional Studies [MeSH]
lokal Animals [MeSH]
lokal Microscopy/instrumentation [MeSH]
lokal Ophthalmologic Surgical Procedures/instrumentation [MeSH]
lokal Intraoperative optical coherence tomography
lokal Original Article
lokal Tomography, Optical Coherence/methods [MeSH]
lokal Ophthalmologic Surgical Procedures/methods [MeSH]
lokal Eye/diagnostic imaging [MeSH]
lokal Computer-aided ophthalmic surgery
lokal Monitoring, Intraoperative/methods [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-3433-4020|https://frl.publisso.de/adhoc/uri/Um9vZGFraSwgSGVzc2Ft|https://frl.publisso.de/adhoc/uri/RXNsYW1pLCBBYm91emFy|https://frl.publisso.de/adhoc/uri/TmF2YWIsIE5hc3Npcg==
1000 Hinweis
  • DeepGreen-ID: f442940a405e444697b8615c1740496f ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
  1. Automatic intraoperative optical coherence tomography positioning
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6468796.rdf
1000 Erstellt am 2023-11-17T18:34:49.173+0100
1000 Erstellt von 322
1000 beschreibt frl:6468796
1000 Zuletzt bearbeitet 2023-12-01T08:28:52.552+0100
1000 Objekt bearb. Fri Dec 01 08:28:52 CET 2023
1000 Vgl. frl:6468796
1000 Oai Id
  1. oai:frl.publisso.de:frl:6468796 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source