Download
s00392-020-01657-2.pdf 1003,55KB
WeightNameValue
1000 Titel
  • Protected risk stratification with the wearable cardioverter-defibrillator: results from the WEARIT-II-EUROPE registry
1000 Autor/in
  1. Veltmann, Christian |
  2. Winter, Stefan |
  3. Duncker, David |
  4. Jungbauer, Carsten G. |
  5. Wäßnig, Nadine K. |
  6. Geller, J. Christoph |
  7. Erath, Julia W. |
  8. Goeing, Olaf |
  9. Perings, Christian |
  10. Ulbrich, Michael |
  11. Roser, Mattias |
  12. Husser, Daniela |
  13. Gansera, Laura S. |
  14. Soezener, Korkut |
  15. Malur, Frank Michael |
  16. Block, Michael |
  17. Fetsch, Thomas |
  18. Kutyifa, Valentina |
  19. Klein, Helmut U. |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-05-06
1000 Erschienen in
1000 Quellenangabe
  • 110(1):102-113
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00392-020-01657-2 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7806570/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Background!#!The prospective WEARIT-II-EUROPE registry aimed to assess the value of the wearable cardioverter-defibrillator (WCD) prior to potential ICD implantation in patients with heart failure and reduced ejection fraction considered at risk of sudden arrhythmic death.!##!Methods and results!#!781 patients (77% men; mean age 59.3 ± 13.4 years) with heart failure and reduced left ventricular ejection fraction (LVEF) were consecutively enrolled. All patients received a WCD. Follow-up time for all patients was 12 months. Mean baseline LVEF was 26.9%. Mean WCD wearing time was 75 ± 47.7 days, mean daily WCD use 20.3 ± 4.6 h. WCD shocks terminated 13 VT/VF events in ten patients (1.3%). Two patients died during WCD prescription of non-arrhythmic cause. Mean LVEF increased from 26.9 to 36.3% at the end of WCD prescription (p < 0.01). After WCD use, ICDs were implanted in only 289 patients (37%). Forty patients (5.1%) died during follow-up. Five patients (1.7%) died with ICDs implanted, 33 patients (7%) had no ICD (no information on ICD in two patients). The majority of patients (75%) with the follow-up of 12 months after WCD prescription died from heart failure (15 patients) and non-cardiac death (15 patients). Only three patients (7%) died suddenly. In seven patients, the cause of death remained unknown.!##!Conclusions!#!Mortality after WCD prescription was mainly driven by heart failure and non-cardiovascular death. In patients with HFrEF and a potential risk of sudden arrhythmic death, WCD protected observation of LVEF progression and appraisal of competing risks of potential non-arrhythmic death may enable improved selection for beneficial ICD implantation.
1000 Sacherschließung
lokal Female [MeSH]
lokal Defibrillators, Implantable [MeSH]
lokal Follow-Up Studies [MeSH]
lokal Heart failure
lokal Heart Failure/physiopathology [MeSH]
lokal Humans [MeSH]
lokal Prospective Studies [MeSH]
lokal Middle Aged [MeSH]
lokal Electric Countershock/methods [MeSH]
lokal Stroke Volume/physiology [MeSH]
lokal Time Factors [MeSH]
lokal Europe/epidemiology [MeSH]
lokal Sudden cardiac death
lokal Morbidity/trends [MeSH]
lokal Ventricular Function, Left/physiology [MeSH]
lokal Heart Failure/epidemiology [MeSH]
lokal Male [MeSH]
lokal Original Paper
lokal Heart Failure/therapy [MeSH]
lokal Wearable cardioverter-defibrillator
lokal Risk Assessment/methods [MeSH]
lokal Registries [MeSH]
lokal Electrocardiography [MeSH]
lokal Implantable cardioverter-defibrillator
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0001-7587-1124|https://frl.publisso.de/adhoc/uri/V2ludGVyLCBTdGVmYW4=|https://frl.publisso.de/adhoc/uri/RHVuY2tlciwgRGF2aWQ=|https://frl.publisso.de/adhoc/uri/SnVuZ2JhdWVyLCBDYXJzdGVuIEcu|https://frl.publisso.de/adhoc/uri/V8Okw59uaWcsIE5hZGluZSBLLg==|https://frl.publisso.de/adhoc/uri/R2VsbGVyLCBKLiBDaHJpc3RvcGg=|https://frl.publisso.de/adhoc/uri/RXJhdGgsIEp1bGlhIFcu|https://frl.publisso.de/adhoc/uri/R29laW5nLCBPbGFm|https://frl.publisso.de/adhoc/uri/UGVyaW5ncywgQ2hyaXN0aWFu|https://frl.publisso.de/adhoc/uri/VWxicmljaCwgTWljaGFlbA==|https://frl.publisso.de/adhoc/uri/Um9zZXIsIE1hdHRpYXM=|https://frl.publisso.de/adhoc/uri/SHVzc2VyLCBEYW5pZWxh|https://frl.publisso.de/adhoc/uri/R2Fuc2VyYSwgTGF1cmEgUy4=|https://frl.publisso.de/adhoc/uri/U29lemVuZXIsIEtvcmt1dA==|https://frl.publisso.de/adhoc/uri/TWFsdXIsIEZyYW5rIE1pY2hhZWw=|https://frl.publisso.de/adhoc/uri/QmxvY2ssIE1pY2hhZWw=|https://frl.publisso.de/adhoc/uri/RmV0c2NoLCBUaG9tYXM=|https://frl.publisso.de/adhoc/uri/S3V0eWlmYSwgVmFsZW50aW5h|https://frl.publisso.de/adhoc/uri/S2xlaW4sIEhlbG11dCBVLg==
1000 Hinweis
  • DeepGreen-ID: 7e78045d684a4d679b546d448817afe8 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6469890.rdf
1000 Erstellt am 2023-11-18T02:22:35.585+0100
1000 Erstellt von 322
1000 beschreibt frl:6469890
1000 Zuletzt bearbeitet 2023-12-01T10:44:44.499+0100
1000 Objekt bearb. Fri Dec 01 10:44:44 CET 2023
1000 Vgl. frl:6469890
1000 Oai Id
  1. oai:frl.publisso.de:frl:6469890 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source