Download
s00392-020-01775-x.pdf 1,53MB
WeightNameValue
1000 Titel
  • Thirty-day incidence of stroke after transfemoral transcatheter aortic valve implantation: meta-analysis and mixt-treatment comparison of self-expandable versus balloon-expandable valve prostheses
1000 Autor/in
  1. Seppelt, Philipp Christian |
  2. Mas-Peiro, Silvia |
  3. De Rosa, Roberta |
  4. Dimitriasis, Zisis |
  5. Zeiher, Andreas M. |
  6. Vasa-Nicotera, Mariuca |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-11-29
1000 Erschienen in
1000 Quellenangabe
  • 110(5):640-648
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00392-020-01775-x |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8099765/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Aims!#!Stroke is a major complication after transcatheter aortic valve implantation (TAVI). Although multifactorial, it remains unknown whether the valve deployment system itself has an impact on the incidence of early stroke. We performed a meta- and network analysis to investigate the 30-day stroke incidence of self-expandable (SEV) and balloon-expandable (BEV) valves after transfemoral TAVI.!##!Methods and results!#!Overall, 2723 articles were searched directly comparing the performance of SEV and BEV after transfemoral TAVI, from which 9 were included (3086 patients). Random effects models were used for meta- and network meta-analysis based on a frequentist framework. Thirty-day incidence of stroke was 1.8% in SEV and 3.1% in BEV (risk ratio of 0.62, 95% confidence interval (CI) 0.49-0.80, p = 0.004). Treatment ranking based on network analysis (P-score) revealed CoreValve with the best performance for 30-day stroke incidence (75.2%), whereas SAPIEN had the worst (19.0%). However, network analysis showed no inferiority of SAPIEN compared with CoreValve (odds ratio 2.24, 95% CI 0.70-7.2).!##!Conclusion!#!Our analysis indicates higher 30-day stroke incidence after transfemoral TAVI with BEV compared to SEV. We could not find evidence for superiority of a specific valve system. More randomized controlled trials with head-to-head comparison of SEV and BEV are needed to address this open question.
1000 Sacherschließung
lokal Aortic stenosis
lokal Transcatheter Aortic Valve Replacement/instrumentation [MeSH]
lokal Humans [MeSH]
lokal Incidence [MeSH]
lokal Self-expandable TAVI
lokal Postoperative Complications/epidemiology [MeSH]
lokal Transcatheter Aortic Valve Replacement/adverse effects [MeSH]
lokal Stroke
lokal Randomized Controlled Trials as Topic [MeSH]
lokal Stroke/epidemiology [MeSH]
lokal Heart Valve Prosthesis [MeSH]
lokal Transcatheter Aortic Valve Replacement/methods [MeSH]
lokal Balloon-expandable TAVI
lokal Original Paper
lokal Aortic Valve Stenosis/surgery [MeSH]
lokal Stroke/etiology [MeSH]
lokal Prosthesis Design [MeSH]
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0003-4743-6920|https://frl.publisso.de/adhoc/uri/TWFzLVBlaXJvLCBTaWx2aWE=|https://frl.publisso.de/adhoc/uri/RGUgUm9zYSwgUm9iZXJ0YQ==|https://frl.publisso.de/adhoc/uri/RGltaXRyaWFzaXMsIFppc2lz|https://frl.publisso.de/adhoc/uri/WmVpaGVyLCBBbmRyZWFzIE0u|https://frl.publisso.de/adhoc/uri/VmFzYS1OaWNvdGVyYSwgTWFyaXVjYQ==
1000 Hinweis
  • DeepGreen-ID: 6899cc82170340b399ef07779aab331e ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6469980.rdf
1000 Erstellt am 2023-11-18T03:05:07.666+0100
1000 Erstellt von 322
1000 beschreibt frl:6469980
1000 Zuletzt bearbeitet 2023-12-01T10:55:31.728+0100
1000 Objekt bearb. Fri Dec 01 10:55:31 CET 2023
1000 Vgl. frl:6469980
1000 Oai Id
  1. oai:frl.publisso.de:frl:6469980 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source