Download
s11678-020-00595-9.pdf 733,23KB
WeightNameValue
1000 Titel
  • Prosthetic replacement of the radial head
1000 Titelzusatz
  • Implantation von Radiuskopfprothesen
1000 Autor/in
  1. Wegmann, Kilian |
  2. Ott, Nadine |
  3. Leschinger, Tim F. |
  4. Harbrecht, Andreas |
  5. Müller, Lars P. |
  6. Hackl, Michael |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-09-09
1000 Erschienen in
1000 Quellenangabe
  • 15(4):310-315
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s11678-020-00595-9 |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • <jats:title>Abstract</jats:title><jats:sec> <jats:title>Background</jats:title> <jats:p>Radial head replacement is an established option in patients with comminuted radial head fractures and complex elbow trauma. While studies demonstrated that asymptomatic radiolucencies around the stem are common, the incidence and clinical significance of bone loss at the proximal part of the radius, just distal to the neck of the prosthesis (collar resorption), is unknown.</jats:p> </jats:sec><jats:sec> <jats:title>Objectives</jats:title> <jats:p>The aim of this retrospective study was to analyse the incidence of collar resorption after radial head replacement and investigate whether this correlates with specific patient characteristics such as gender, age, indication for index surgery and the size of implant used.</jats:p> </jats:sec><jats:sec> <jats:title>Materials and methods</jats:title> <jats:p>The study group consisted of 30 patients (average age 60.1 years) having undergone prosthetic replacement with a monopolar press-fit implant of the radial head at an average follow-up of 23 months. Indications for surgery included trauma sequelae or revision in 16 patients and acute, unreconstructable fractures of the radial head in 14 cases. Symptoms of loosening and revision surgery were recorded. Radiographs were analysed for signs of lucency between the bone and the implant as well as for signs of resorption of bone mass around the neck (section 1). These values were correlated with age, gender, indication for index surgery and size of implant.</jats:p> </jats:sec><jats:sec> <jats:title>Results</jats:title> <jats:p>In all, 28/30 (93.3%) prostheses showed proximal osteolysis around the neck of the shaft. Of the 30, one prosthesis presented signs of shaft loosening. The average amount of osteolysis was 8.78% (range 0–26.1%; ±6.0%) of the overall length of the prosthetic shaft (OL). There was no significant difference (<jats:italic>p</jats:italic> = 0.49) between the amount of resorption in section 1 between the primary fracture cases (8.75 ± 4.5%; range 1.2–15.8%) and the group of secondary implantations due to degeneration or fracture sequelae (8.8 ± 7.2%; range 0–26.1%). Furthermore, the analysis did not reveal any statistically relevant correlations between the amount of neck resorption and the other cohort characteristics (age, gender, size of the components).</jats:p> </jats:sec><jats:sec> <jats:title>Conclusions</jats:title> <jats:p>In the study cohort, a high amount of osteolysis/bone resorption was assessed around the neck of the press-fit radial head prosthesis used. However, no significant correlation between collar resorption, patient demographics and indication for index surgery was found at short-term follow-up.</jats:p> </jats:sec>
1000 Sacherschließung
lokal Prothese
lokal Revision
lokal Prosthesis
lokal Knochenresorption distal des Prothesenhalses
lokal Original Contribution
lokal Loosening
lokal Collar resorption
lokal Lockerung
lokal Osteolyse
lokal Radial head replacement
lokal Osteolysis
lokal Radiuskopfprothese
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/V2VnbWFubiwgS2lsaWFu|https://frl.publisso.de/adhoc/uri/T3R0LCBOYWRpbmU=|https://frl.publisso.de/adhoc/uri/TGVzY2hpbmdlciwgVGltIEYu|https://frl.publisso.de/adhoc/uri/SGFyYnJlY2h0LCBBbmRyZWFz|https://frl.publisso.de/adhoc/uri/TcO8bGxlciwgTGFycyBQLg==|https://frl.publisso.de/adhoc/uri/SGFja2wsIE1pY2hhZWw=
1000 Hinweis
  • DeepGreen-ID: cfdca11f8de24cda9ed50683cf8568b1 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
  1. Prosthetic replacement of the radial head
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6471558.rdf
1000 Erstellt am 2023-11-18T14:07:45.050+0100
1000 Erstellt von 322
1000 beschreibt frl:6471558
1000 Zuletzt bearbeitet Thu Apr 04 09:16:11 CEST 2024
1000 Objekt bearb. Thu Apr 04 09:16:11 CEST 2024
1000 Vgl. frl:6471558
1000 Oai Id
  1. oai:frl.publisso.de:frl:6471558 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source